Thread any relay wires, contact wires, and external thermistor 

wires from the wall through the openings in the tray and to the 

terminal block.

T

C1

C2

Cm

C3

C4

PWR Cm

Note: 

The two 

Cm

 (common/ground) pins are connected and 

can be used interchangeably.

Insert and tighten the mounting screws.

Note: 

You may optionally choose to use robust two-sided 

tape to mount the tray assembly to the wall or other flat 

surface, as long as the tape won’t prevent the back of the 

tray from sitting flush against the mounting surface.

10 

Connect the wires from the tray to the terminals in the cover, 

matching the proper wires to the target terminal locations. The 

pin/terminal definitions are defined within Composer Pro. See 

“Configuring” on the next page. (Pins Cm and PWR are used for 

optional external power connections.)

Important! 

When using multiple external contact sensors, or 

when using an external contact sensor along with an external 

thermistor, you MUST connect each device to one of the Cm 

pins in addition to the appropriate sensor or thermistor pin 

to make a proper wiring connection. See the “Sample wiring 

configurations” section of this document for examples.

11 

Attach the cover assembly to the tray: 

A.

 Align the cover edge’s two 

latching tabs with corresponding 

tab receivers on the tray’s edge.

B.

 Close the cover by rocking 

it toward the other end of the 

tray until it snaps into place with 

the tray.

A

B

12 

For Zigbee to IR, connect any IR emitters to the two IR ports, then 

affix the emitter head to the IR window on the device to control 

(such as a TV).

Connecting alternate DC power

Although a power adapter is included, you may elect to instead 

connect an alternate 5-24V DC or AC power source to pins 

Cm

-

PWR

Connect DC positive polarity to pin 

PWR

, and negative to pin 

Cm

.

T

C1

C2

Cm

C3

C4

PWR Cm

DC power

3/8˝

(9.5 mm)

+

Configuring

Connections

Static connections

Some connections in the driver are static in that they are always 

available regardless of any settings/options. These include the 

two IR connections, IR Output 1 and IR Output 2, and the internal 

contact.

Dynamic connections

Other connections in the driver are dynamic in that the 

connections will appear based on certain options—in particular, 

the 

IO Options

 property. 

If you change to another IO option, any 

connections created in the original IO option will be broken

.

To configure your device:

Add the device to your Composer Pro project. When prompted to 

identify the device, press the ID button on the face of the cover 

four times. The green LED blinks twice to confirm the ID has been 

sent to the Control4 system.
- OR -
In Composer Express, add a device into the project, scan for 

Zigbee devices, then press the ID button on the face of the cover 

four times. 

In the driver’s 

Properties 

tab, view or configure the settings 

explained below under “Properties,” then click 

Set 

to the right of 

the setting after each change.

Configure each relay’s power up state. This is the state you want 

the relay to adopt after a device reboot. For example, after a 

power outage (resulting in a device reboot), you may want the 

garage door to default to closed, the window coverings to be 

restored to their last known state, and the fireplace to be turned 

off.

Tip: 

Two SPST relays can optionally be linked to simulate a 

single SPDT relay. However, unlike a true SPDT relay, both 

relays will open during a power failure.

Summary of Contents for Zigbee IO C4-Z2IO

Page 1: ...at the device resulting in faster IR control response times Micro USB IR 1 IR 2 Note Y IR cables can be used or IR cables can be spliced together in parallel not in series to increase the number of c...

Page 2: ...failure Relay 1 is wired to pin C1 and pin C2 Relay 2 is wired to pin C3 and pin C4 As a thermistor and humidistat The device contains an integrated thermistor and humidistat as well as a connection f...

Page 3: ...r ZCA EXT10A AC DOTS1 W AC PMT51 W Installing 1 Place the device in a location which ensures the following Easy access to any externally connected wires Zigbee mesh networking efficiency Note Make sur...

Page 4: ...power Although a power adapter is included you may elect to instead connect an alternate 5 24V DC or AC power source to pins Cm PWR Connect DC positive polarity to pin PWR and negative to pin Cm T C1...

Page 5: ...ons include Fahrenheit and Celsius Default is Fahrenheit Local Temperature Read only Shows the most recent reported temperature recorded by the internal thermistor The scale of the temperature is dete...

Page 6: ...g Reboot the device by disconnecting power then re connecting power Check for proper wiring See the Wiring Configuration diagrams Review the log in the driver s Lua tab Restore factory defaults 13 but...

Page 7: ...vice at 866 424 4489 Find other legal resources such as regulatory notices and patent information at snapav com legal 200 00466 E 2021 08 27 DH Copyright 2021 Snap One LLC All rights reserved Snap One...

Reviews: