Page 1: ...Mars Line Scan GigE Camera User Manual Using iCentral with Mars Line Scan GigE Cameras...

Page 2: ...other equipment connected to our camera Handle this camera with care Do not abuse the camera Avoid striking shaking etc The camera could be damaged by improper handling Do not open the housing and do...

Page 3: ...a Installation 7 3 iCentral Installation 7 4 iCentral Panes Description 10 4 1 Tool Bar 10 4 2 Visibility 11 4 3 Parameters Pane 12 4 3 1 Device Control 12 4 3 2 Image Format Control Descriptions 12 4...

Page 4: ...ce Compact appearance 62 62 35mm On board buffer 256MB for data transmission and image reload under burst mode Support API trigger External trigger Free Run mode and other trigger mode Support sharpne...

Page 5: ...5 1 3 2 Interface Description The description of each interface as shown in Figure 1 2 Figure 1 2 Interface Description...

Page 6: ...is connected with the device free mode with image transmission Slow Flashing Blue Using trigger mode Red Blue Flashing Alternately Red and Blue Firmware is upgrading Abnormal Red Steady Red Device mal...

Page 7: ...e installation position Connect the camera with right lens 2 Connect the camera to the PC network card by Gigabit Ethernet cable CAT5E or CAT6 3 Choose one of the following power supply methods DC pow...

Page 8: ...8 Note Please check the following item...

Page 9: ...f there is a new camera in the network it is required to click refresh in order to refresh the device list 5 Double click the device or click button for device connection and disconnection Explanation...

Page 10: ...e iCentral are described in the figure below 4 1 Tool Bar File For user configuration User can do the following operations open open recent save and save as Tool bar Parameters Pane Message Window Con...

Page 11: ...ow the instruction to change data 4 2 Visibility All camera features have a Visibility attribute which defines its requirement or complexity The states vary from Beginner features required for basic o...

Page 12: ...anging all acquisition parameters supported by the acquisition device Parameters in gray are read only either always or due to another feature being disabled Parameters in black are user set in iCentr...

Page 13: ...ixels ReverseX ReverseX False True Flip horizontally the image sent by the device The Region of interest is applied after the flipping PixelFormat PixelFormat Mono8 Mono10 Mo no10Packed Mono1 2 Mono12...

Page 14: ...s to capture during an acquisition and the way the acquisition stops Frames are captured continuously with AcquisitionStart until stopped with the AcquisitionStop command One frame is captured for eac...

Page 15: ...using AcquisitionStatus Device is currently waiting for a trigger to capture one or more frames Device is currently waiting for a frame trigger AcquisitionStatus AcquisitionStatus True False Reads th...

Page 16: ...ight ResultingLineRateAbs ResultingLineRateAbs Indicates the absolute value of the maximum allowed acquisition frame rate The absolute value is a float value that indicates the maximum allowed acquisi...

Page 17: ...tures Display Name Feature Values Description LineSelector LineSelector Selects the physical line or pin of the external device connector to configure LineMode LineMode Selects the physical line or pi...

Page 18: ...ectionLevel LineDetectionLevel Threshold3V3 Threshold5V LineDebouncingPeriod LineDebouncingPeri od Min 3 40282e 38 Max 3 40282e 38 Default in nanosecond ns 4 3 5 EventControl The following table descr...

Page 19: ...a Min 0 Max 3 99998 Controls the gamma correction of pixel intensity This is typically used to compensate for non linearity of the display system such as CRT 4 3 7 LUTControl The following table descr...

Page 20: ...iveLinkCount GEVActiveLinkCount Indicates the current number of active logical links GEVInterfaceSelector GEVInterfaceSelector Selects which logical link to control GEVMACAddress GEVMACAddress MAC add...

Page 21: ...IP Configuration is not defined Device IP Address Configuration is set to Persistent IP static Device IP Address Configuration is set to DHCP Dynamic Host Configuration Protocol Network requires a DH...

Page 22: ...ndicates the number of message channels supported by this device GevStreamChannelCount GevStreamChannelCount Indicates the number of stream channels supported by this device GevHeartbeatTimeout GevHea...

Page 23: ...elSelector Selects the stream channel to control GevSCPInterfaceIndex GevSCPInterfaceIndex Index of the logical link to use GevSCPHostPort GevSCPHostPort Controls the port of the selected channel to w...

Page 24: ...ion IP address from which a GVSP receiver may receive data stream Static IP Configuration Configures the following parameters in TransportLayerControl GevCurrentIPConfigurationLLA True GevCurrentIPCon...

Page 25: ...ccess Reports the last user set executed by the device from a user set load command or as a result of a device reset 4 3 10 CounterAndTimerControl The following table describes each Counter and Timer...

Page 26: ...hift DigitalShift Min 0 Max 4 Sets the value of the selected digital shift control FPNcalibrationStatus FPNcalibrationStatus Fixed pattern noise correction calibration status FPNAlgorithmSelector FPNA...

Page 27: ...27 Hangzhou Contrstech Co Ltd Add No 11 Xiyuan 8th Road West Lake District Hangzhou 310030 China TEL 86 571 89712238 Fax 400 8266 163 01460 Web site www contrastech com E mail market contrastech com...