CONTRACOR
®
CAB-110S/CAB-135S Art. 10115105/10115106
21
5.2 Service maintenance
5.2.1 Gloves
Special static-dissipating gloves have been provided for operator comfort. It will be
necessary to change gloves periodically as they wear. The first sign of deterioration may be
excessive static shocks. Gloves are held in place by metal clamps on the inside of the cabinet.
To replace, loosen the clamps with a screwdriver, replace the gloves, and tighten the clamps.
5.2.2 Nozzle
Replace the nozzle when its diameter has increased by max. 2mm or sooner if pressure
diminishes noticeably.
To change the nozzle, unscrew the holding nut from the gun end. Pull the nozzle from
the gun and replace with a new nozzle, placing the tapered end toward the jet. Screw the
holding nut back onto the gun.
10
11
9
2
8
4
3
1
12
7
6
5
13
Picture 5.1.6.
Changing the rubber
shield of the reclaimer
(10) from the flange (2), loosen the nuts (11)
and remove the flange (2) from the reclaimer
(1). Inspect the condition of the rubber shield
(3). To change the shield, unscrew the bolts
(12)(13), and remove the shield (3), the strip
(4), the tightening piece (7) and the pipe bend
(5). Reassemble the reclaimer in the reverse
order, replacing the gaskets (8)(6) if required.