DC:AV (Activation value)
DC:DV (Deactivation value)
DC:I (Integrator time)
DC:CR (Integrator limitation)
Command
Parameter
Unit
Group
DC:AV
x
DC:DV
x
DC:I
x
DC:CR
x
x= 0… 2000
x= 0… 1000
x= 0… 2000
x= 0… 500
0.01 %
0.01 %
ms
0.01 %
EXP
DC:AV
This parameter is used to define the activation point (activation value). The DC
function is completely deactivated in case of DC: AV = 0.
DC:DV
This parameter is used to define the deactivation point (DV = deactivation
value) Within the deactivation window no compensation value will be calculated
(frozen state). DC: AV
= 0 should be used for best positioning, but „limit cycling
“can occur. This value should be set to 50 % of an acceptable error.
DC:I
This parameter is used to define the integrator time. The lower this value the
faster the compensation. Low values will result in „limit cycling“.
DC:CR
the output range of the DC function will be limited (CR = control range) by this
parameter.
PROCESS DATA (Monitoring)
Command
Description
Unit
WA
W
V
X
E
C
U
IA
IB
Demand value (input signal)
Demand value (according to the profile generator)
Speed input
Actual value
Error value
Output of the controller
Output signal of the module
Solenoid current A
Solenoid current B
mm
mm
%
mm
mm
%
%
mA (P Version only)
mA (P Version only)
The process data are the variables which can be observed continuously on the
monitor or on the oscilloscope