Speed commands
The SIGNAL: V command is used to switch over between external or internal speed limitations.
SIGNAL: V = OFF
Internal speed limitation (VELO command)
SIGNAL: V = U0-10
External speed limitation (0-10 Volt)
PIN 9/10 is used for external speed limitation
3
.
See
ANIMODE
section (page 24-25) if the Signals used are not listed above, for re-scaling as
required.
VELO (Internal speed demand value)
Command
Parameters
Unit
Group
VELO
x
x= 1… 10000
0.01 %
SIGNAL:V =
OFF
Specification of the internal speed limitation.
VRAMP (Ramp time for external speed demand)
Command
Parameters
Unit
Group
VRAMP
x
x= 10… 5000
ms
SIGNAL:V
The rate of change of the external speed demand can be limited by this ramp time. The command
is only active if external speed demand (SIGNAL:V <> OFF) has been parameterized.
3
The output signal is directly limited in SDD mode (default mode). In NC mode the speed profile of the
generator is limited. The lowest adjustable speed is 0.01 mm/s (VMAX = 1 mm/s and VELO = 1 %).