![Continental Hydraulics CEM-SA-B Installation Manual Download Page 17](http://html1.mh-extra.com/html/continental-hydraulics/cem-sa-b/cem-sa-b_installation-manual_2657177017.webp)
Continental Hydraulics Installation Manual
Page 17 of 27
CEM-SA-B
CHI 1020687 01/2016
A:A and A:B (Acceleration (ramp) time)
Command
Parameters
Unit
Group
A:i x
i= A|B
x= 1… 5000
ms
VMODE=SDD
Ramp function for the 1
st
(A solenoid) and 3
rd
(B solenoid) acceleration quadrants only.
The acceleration time for positioning is dependent on the direction. “A” corresponds to connection
15 and “B” corresponds to connection 16 (if POL = +).
Normally A = flow P-A, B-T and B = flow P-B, A-T.
For quadrants 2 and 4, parameters D:A and D:B are used as the deceleration distance demand
when the SDD funcion is in control.
D:A / D:B / D:S (Deceleration / braking distance)
Command
Parameters
Unit
Group
D:i x
i= A|B|S
x= 1… 10000
mm
VMODE = SDD
This parameter is specified in mm
4
.
The deceleration stroke is set for each direction of movement (A or B). The control gain is
calculated internally depending on the deceleration distance. The shorter the deceleration
distance, the higher the gain. A longer deceleration distance should be specified in the event of
instability.
Parameter D:S is used as the stopping ramp when disabling the START (PIN 7) signal. After
disabling, a new target position (current position plus D:S) is calculated in relation to the speed
and is specified as a command value.
i
Intern
D
STROKE
G
Calculation of control gain
CAUTION:
If the maximum stroke (SYS_RANGE command) is changed, the deceleration
distance must also be adjusted. Otherwise this can result in instability and uncontrolled
movements.
4
CAUTION!
In older modules this parameter was specified in % of the maximum stroke. Since data
specification for this module has now been converted to mm, the relationship between the stroke
(SYS_RANGE command) and these parameters must be taken into account.