![Continental Hydraulics CEM-AA-B Installation Manual Download Page 5](http://html1.mh-extra.com/html/continental-hydraulics/cem-aa-b/cem-aa-b_installation-manual_2657169005.webp)
Continental Hydraulics Installation Manual
Page 5 of 33
CEM-AA-B
CHI 1020611 01/2016
Steps to install and configure a new application:
All parameters are adjusted using VEA-BUSB programming cable and CHI-PC Microsoft
Windows application.
1. Mount the module in a suitable location
2. Connect the power supply and valve solenoids
3. Down load and open the GUI program (
www.continentalhydraulics.com/wp-
content/uploads/2015/01/setup-CEWMPC-10-v3.5.0.zip
)
4. Connect to Laptop via USB to USB Type B communication cable.
5. Open the Options Tab and in setting, verify that the correct com port, full-Duplex and
57.6K Baud rates are selected.
6. Select Desired Function (AA / A-B / RA) for your application as desired, Click the ID
button to update the Parameter list.
7. Adjust current range to match valve
8. Adjust PWM / Dither to optimize performance of the valve
9. Adjust analog input to voltage or current, and scale input if required.
10. Adjust ramping (if desired)
11. Adjust internal monitor functions (if desired)
12. Adjust current output to the valve for the flow / pressure required (if desired)