CEM-AA-B
CHI 1020611 01/2016
AA and AB (Ramp function/Acceleration time)
Commando
Parameters
Unit
Group
FUNCTION
AA:I X
AB:I
X
i= UP|DOWN
x= 1… 120000
x= 1… 120000
ms
ms
STD
A-B
Two quadrant ramp function.
The first quadrant means the ramp up and the second quadrant means the ramp down time. The
ramp time is related to 100 % signal step.
AA (Ramp function)
Command
Parameters
Unit
Group
FUNCTION
AA:I
X
i= 1… 4
x= 1… 120000
-
ms
STD
AA
RA
– 4Q Mode
Four quadrants ramp function.
The first quadrant means the acceleration ramp for solenoid A and the second one stands for the
deceleration ramp of solenoid A. According to this the third quadrant represents the acceleration
ramp for solenoid B so that the fourth quadrant remains for the deceleration ramp for solenoid B.
t
A
u
s
g
a
n
g
A
/O
u
tp
u
t
A
AA:UP
AA:DOWN
A
u
s
g
a
n
g
B
/O
u
tp
u
t
B
AB:UP
AB:DOWN
t
A
u
sg
a
n
g
/O
u
tp
u
t A
A
u
sg
a
n
g
/O
u
tp
u
t
B
AA:1
AA:2
AA:3
AA:4