W415-1350 / 12.16.14
23
EN
DO NOT BUILD INTO THIS AREA - IT MUST BE LEFT
CLEAR TO PROVIDE ADEQUATE CLEARANCE FOR
THE VENT IN THIS 14” (355.6MM) WIDE AREA
CENTERED ALONG THE FRONT OF THE
APPLIANCE. NO COMBUSTIBLES ARE ALLOWED.
!
WARNING
NOTE: Three braces are
required (as nailers).
84"
2134mm *
40 3/4"
1035mm
3 1/2"
89mm
MAX
14"
356mm
MIN
1 1/2"
38mm
MAX
20 1/4"
514mm **
41 1/4"
1047mm *
It is best to frame your appliance after it is positioned and the vent system is installed. Frame to local building codes.
It is not necessary to install a hearth extension with this appliance.
* Allow for
fi
nished
fl
oor and hearth thickness when setting these dimensions.
** When constructing the enclosure allow for
fi
nishing material thickness to maintain clearances.
When roughing in the appliance, raise the appliance to accommodate for the thickness of the
fi
nished
fl
oor materials,
i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower access door and the
installation of many decorative
fl
ashing accessories.
Combustible materials may be installed
fl
ush with the front of the appliance but must not cover any of the black face-
areas of the appliance. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.