W415-4006 / A / 03.01.22
EN
24
installation
3.3.3 installing natural vent
Follow the instructions of the natural vent manufacturer for chimney
installation.
A.
Remove and discard the two combustion air cover plates
and gaskets located on the rear panel of the appliance.
B.
Replace the four screws per side to secure the rear panel to
the appliance.
C.
Remove the spill switch bracket from the rear of the adapter.
D.
Gently pull the two wire terminals (located inside the
7" (178mm) flue collar at the top of the appliance) out
approximately 8" (203mm).
E.
Bring the wires through the lower hole in the adapter and
out the spill switch opening. To pass the wires through
the hole more easily, temporarily tape the two terminals
together.
F.
With the spill switch opening aligned to the back of the
appliance, push the crimped edge of the adapter in to the
appliance flue collar.
G.
Connect the wire terminals to the spill switch and re-secure the
bracket.
H.
Secure the terminal block into place as shown with the screw
supplied.
I.
Unscrew the wire access cover plate from the rear right hand
side below the firebox. Remove and discard the gasket.
Remove the knockout from the cover plate and insert the
protective bushing. Pull both spill switch wires through the
bushing taking up any slack. Replace the cover plate.
FOR
Disconnect one of the black on/off switch wires connected to the control module and connect it to the
other side of the terminal block. Connect the other white spill switch wire to the control module (see
"wiring diagram (electronic)").
For aesthetics, the adapter has been
designed to accept a standard matte
black 7" (178mm) stove pipe and the
decorative band (standard with the GS-
150KT). Both are available from your
local authorized dealer / distributor.
3.3.4 natural vent
Attach the Natural Vent label, shown, in the control area of the appliance.
SPILL
SWITCH
ADAPTER
B-VENT ADAPTER
NO B-VENT ADAPTER
WIRES (GDS28)
SWITCH
SPILL
ADAPTER
COMBUSTION AIR COVER
PLATES AND GASKET
NOTE: If not converting, the wires
are rated for high temperatures
and may remain as is in the appli-
ance collar.
NO B-VENT ADAPTER
WIRES (GDS28)
TERMINAL BLOCK
WIRE ACCESS
COVER PLATE
block and to terminal 3 on the gas
standard matte black 7" (178mm) stove pipe and the decorative band (standard with the GS-150KT).
Both are available from your local authorized dealer / distributor.
ATTACH THIS LABEL IN THE CONTROL AREA OF THE APPLIANCE.
THIS APPLIANCE HAS BEEN CONVERTED TO A NATURAL VENT
MODEL.
ATTACHEZ CET ÉTIQUETTE DANS LA RÉGION DE CONTRÔLE DU FOYER.
CET APPAREIL A ÉTÉ CONVERTI À UN MODÈLE À TIRAGE
NATUREL.
TITLE:
NATURAL VENT LABEL GS-150KT
REVISIONS: B:
CORRECTED ADHESIVE TEMPERATURE LIMIT ||
09.22.16_J.K.
B
DATE:
01.13.99
DWG#:
W385-0160
MATERIAL:
CLASS III A-2, PERMANENT LABEL, WATERPROOF, NON-WATER
SOLUBLE ADHESIVE, CAPABLE OF WITHSTANDING 175° F (29° C) TEMPERATURE.
SILVER LETTERING ON BLACK BACKGROUND.
MAX OVERALL DECAL SIZE:
4” X 1”
W385-0160 / B