Continental Fireplaces CDIZC - N Installation And Operating Instructions Manual Download Page 8

8

W415-0224 / G / 02.28.11

2.5  RATING PLATE INFORMATION

INSTALLER: It is your responsibility to 
check off the appropriate box on the rating 
plate according to the model, venting and 
gas type of the appliance.

For rating plate location, see “INSTALLATION 
OVERVIEW” section.

This illustration is for reference only. Refer to 
the rating plate on the appliance for accurate 
information.

W385-0198 / G

SERIAL NUMBER

NO. DE SERIE

GDIZC / CDIZC

 

GDIZC-N / CDIZC-N 

MODEL 

GDIZC-P / CDIZC-P

 

0 - 4500FT 

ALTITUDE/ELEVATION 

0 - 4500FT

 

24,000 BTU/h 

INPUT / ALIMENTATION 

24,000 BTU/h

 

14,000 BTU/h 

REDUCED INPUT / ALIMENTATION REDUITE 

15,000 BTU/h

 

17,160BTU/h 

OUTPUT / RENDEMENT 

17,160 BTU/h

THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE ONLY WITH 
A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD. APPROVED FOR BEDROOM, 
BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION 
IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS 
EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED 
HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US 
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR 
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.

CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE.  REMPLACEZ 
UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE. 

HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET 
UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLA-
TION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS 
MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE 
SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 
3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER 
A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR 
LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMU-
NAUTES, ANSI/NFPA 501A.

STEADY STATE EFFICIENCY (NG/LP): 

71.5% FAN OFF / 73% FAN ON

EFFICACITE CONSTANTE (GN/P): 

71.5% VENT. ARRETE / 73% VENT. FONCTIONNE

STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY  / L'EFFICACITE CONSTANTE 
S'APPLIQUENT SEULEMENT AU CANADA.

AFUE (NG/LP) (GN/P): 

65%

MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS ARE 7 FEET AND 35 FEET
RESPECTIVELY. LES LONGUEURS VERTICALES MINIMALES ET MAXIMALES SONT 7 PIEDS ET 
35 PIEDS RESPECTIVEMENT.

MANIFOLD PRESSURE:

 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP)

PRESSION AU COLLECTEUR :

 3.5" D'UNE COLONNE D'EAU(GN) / 10" D'UNE COLONNE D'EAU (P)

MIN SUPPLY PRESSURE:

 4.5" W.C.(NG) / 11" W.C. (LP)

PRESSION D'ALIMENTATION MIN :

 4.5" D'UNE COLONNE D'EAU (GN) / 11" D'UNE COLONNE 

D'EAU (P)

MAX. SUPPLY PRESSURE:

 7" W.C. (NG) / 13" W.C. (LP)

PRESSION D'ALIMENTATION MAX :

 7" D'UNE COLONNE D'EAU (GN) / 13" D'UNE COLONNE 

D'EAU (P)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.

WARNING:

 DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT 

WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE 
APPLIANCE.

AVERTISSEMENT :

 N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT

ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET 
APPAREIL PAR LE FABRICANT.

ELECTRICAL RATING / CLASS.:

 115V 1.5AMP 60HZ

THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE 
OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND 
RESEALING IS NECESSARY AFTER SERVICING THE VENTAIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A 
WOLF STEEL. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION 
PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR 
ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.

WARNING:

 FOR INSTALLATION INTO A VENTED NON-COMBUSTIBLE FIREPLACE

ONLY. THE MINIMUM FIREPLACE SIZE IS: HEIGHT 14 1/2”, DEPTH 11”, WIDTH 25”. THE MINIMUM 
INSIDE FLUE SIZE IS 7”. THE MINIMUM DISTANCE, FROM THE BOTTOM OF A COMBUSTIBLE 
MANTLE PROJECTING A MAXIMUM 3” FROM THE WALL TO THE TOP OF THE STANDARD TRIM IS 
3”. SEE OWNERS MANUAL FOR GREATER EXTENSIONS.

ATTENTION :

 POUR INSTALLATION DANS UN FOYER VENTILE EN MACONNERIE.

LES DIMENSIONS MINIMUMS SONT: HAUTEUR 14 1/2”, PROFONDEUR 11”, LARGEUR 25”. LE 
DIAMETRE INTERIEUR MINIMUM DE CONDUIT D’EVACUATION EST DE 7”.
LA DISTANCE MINIMALE, DU BAS DU MANTEAU COMBUSTIBLE FORMANT UNE
PROJECTION MAXIMALE DE 3” DU MUR AU DESSUS DE LA GARNITURE NORMALE EST 3”. 
REFERER AU MANUEL D’INSTALLATION POUR DES EXTENSIONS PLUS GRANDES. 

NOT FOR USE WITH SOLID FUEL / UN COMBUSTIBLE

SOLIDE NE DOIT PAS ETRE UTILSE AVEC CET APPAREIL

WOLF STEEL LTD.

24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA

9700539 (WSL) 

 

4001657 (NGZ) 

4001658 (NAC) 

 

4001659 (WUSA)

CERTIFIED UNDER: CSA 2.33-2009, ANSI 
Z21.88-2009 VENTED GAS FIREPLACE 
HEATER. 

HOMOLOGUE SELON LES NORMES: CSA 

2.33-2009, ANSI Z21.88-2009 FOYER 

DE CHAUFFAGE AU  GAZ AVEC 

EVACUATION.

SAMPLE

SAMPLE

M,

,

ION

ON 

ES GAS

S GAS 

RED 

RED 

THIS US 

THIS US 

IA FOR

FOR 

FPA 501A.

A

REMPLACEZ

TEEL LTÉE.

R, UNE SALLE DE BAIN ET 

R, UNE SALLE DE BAIN ET 

MOBILE SI SON INSTALLA

MOBILE SI

-

0MH SERIE DE MAISONS

H SERIE DE M

UX ETATS-UNIS DE LA NORME DE

S-UNIS DE LA NORME DE 

CTUREES, TITRE 24 CFR, SECTION

TUREES, TITRE 24 CFR, SECTION 

E PEUT ETRE APPLIQUEE, SE REFERE

E PEUT ETRE APPLIQUEE, SE REFER

E SECURITE CONTRE L'INCENDIE POU

 SECURITE CONTRE L'INCENDIE PO

ACTURES, LES SITES ET LES COMMU

CTURES, LES SITES ET LES COMMU

FAN OFF / 73% FAN ON

FAN OFF / 73% FAN ON

ENT. ARRETE / 73% VENT. FONCTION

ENT. ARRETE / 73% VENT

O CANADA ONLY  / L'EFFICACITE CON

O CANADA ONLY  / L'EFFICACI

ADA.

A.

CAL VENT LENGTHS ARE 7 FEET AND

CAL VENT LENGTHS ARE 7 FEET AND

EURS VERTICALES MINIMALES ET MA

EURS VERTICALES MINIMALES ET 

NT.

NT.

:

 3.5 INCHES W.C. (NG) / 10 INCHES W

NCHES W.C. (NG) / 10 INCHES W

ECTEUR :

 3.5" D'UNE COLONNE D'EAU

3.5" D'UNE COLONNE D'E

SSURE:

SSU

 4.5" W.C.(NG) / 11" W.C. (LP)

.(NG) / 11" W.C. (LP)

LIMENTATION MIN :

LIMENTATIO

 4.5" D'UNE COLON

5" D'UNE CO

PPLY PRESSURE:

Y PRESSURE:

 7" W.C. (NG) / 13" W.

 7" W.C. (NG) / 13" W

SION D'ALIMENTATION MAX :

LIMENTATION MAX :

 7" D'UNE

 7" D'UN

AU (P)

OR USE WITH GLASS DOORS CERTIF

OR USE WITH GLASS DOORS CERTIF

UTILISER AVEC LES PORTES VITRE

UTILISER AVEC LES PORTES 

WARNING:

WARNIN

 DO NOT ADD ANY MAT

DO NOT ADD ANY

WITH THE FLAMES, OTHER TH

WITH THE FLAMES, OTHER TH

APPLIANCE.

APPLIANCE.

AVERTISSEMENT :

AVERTISSEMENT :

N'AJO

 N'AJO

ENTRER EN CONTACT

ENTRER EN CONTA

APPAREIL PAR LE F

AREIL PAR LE 

ELECTRICAL RA

ECTRICAL RA

HE APPLIANC

HE APPLIAN

NERS IN

L

Summary of Contents for CDIZC - N

Page 1: ...r gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier This appliance may be installed as an OEM installation in man...

Page 2: ...REMOVAL AND INSTALLATION 13 4 3 LOG PLACEMENT 14 4 4 GLOWING EMBERS 14 4 5 LOGO PLACEMENT 15 4 6 ALUMINUM EXTRUSION TRIM KIT INSTALLATION 15 5 0 OPERATION 16 6 0 ADJUSTMENTS 17 6 1 PILOT BURNER ADJUST...

Page 3: ...IMNEY CONNECTION section Trim see ALUMINUM EXTRUSION TRIM KIT INSTALLATION section Door see DOOR REMOVAL AND INSTALLATION section Rating Plate see RATING PLATE INFORMATION section Logs see LOG PLACEME...

Page 4: ...tive that the control compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system should be inspected before...

Page 5: ...h the appliance is to be installed is HEIGHT 14 5 WIDTH 25 DEPTH 11 The minimum allowable chimney flue size is 6 round 2 2 MINIMUM OPENING 44 7 8 36 1 2 4 SIDED BACKER PLATE ALUMINUM TRIM 36 15 1 2 25...

Page 6: ...n where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood flooring...

Page 7: ...er Column When the appliance is installed at elevations above 4 500ft and in the absence of specific recommendations from the local authority having jurisdiction the certified high altitude input rati...

Page 8: ...IL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT ELECTRICAL RATING CLASS 115V 1 5AMP 60HZ THE APPLIANCE MUST BE VENTED USIN...

Page 9: ...NON COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES USE WOLF STEEL LTD SUPPORT RING ASSEMBLY W010 0370 OR EQUIVALENT NON COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARA...

Page 10: ...chimney with screws and plugs not supplied C INSIDE Attach and secure the flex liners to the vent connection assembly using the same procedure as before ensuring that the marked exhaust liner is attac...

Page 11: ...use open flame WARNING RISK OF FIRE EXPLOSION OR ASPHYXIATION ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING...

Page 12: ...ANY NON COMBUSTIBLE MATERIALS SUCH AS BRICK MARBLE GRANITE ETC PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED DO NOT STRIKE SLAM OR SCRATCH GLASS DO NOT OPERATE A...

Page 13: ...ERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS LOUVRES OPENINGS OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS BEFORE DOOR...

Page 14: ...heat activated curing process A Place the rear log 1 onto the two log supports and against the air intake pipe B Position logs 2 and 3 against the grate posts and line up the studs located on the burn...

Page 15: ...cluded with each kit If this appliance is being installed into an existing wood burning zero clearance fireplace then be aware of this precaution Any circulation air opening may be covered with noncom...

Page 16: ...ERATION FOR YOURSAFETY READBEFOREOPERATING POUR VOTRE SECURITE LIRE AVANT DE FAIRE FONCTIONNER WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY D...

Page 17: ...ADINGS TIGHTEN SCREWS FIRMLY TO SEAL DO NOT OVER TORQUE LEAK TEST 39 6 PILOT BURNER THERMOCOUPLE THERMOPILE P I L O T PILOT SCREW A B 6 2 VENTURI ADJUSTMENT This appliance has an air shutter that has...

Page 18: ...FLAME MUST ENVELOPE UPPER 3 8 TO 1 2 OF THERMOCOUPLE THERMOPILE 6 3 FLAME CHARACTERISTICS 6 4 RESTRICTING VERTICAL VENTS Some vent configurations may display a very active flame If this appearance is...

Page 19: ...nd bottom of the door is not broken or missing Replace if necessary 8 If for any reason the vent air intake system is disassembled re install and re seal per the instructions provided for the initial...

Page 20: ...the gasket holding the glass in place Careful not to break the glass GLASS GASKET DOOR FRAME GLASS RETAINER WARNING DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED CAR...

Page 21: ...k on Because the blower is thermally activated when turned on it will automatically start approximately 5 15 minutes after lighting the appliance and will run for approximately 30 45 minutes after the...

Page 22: ...T IS AN INTEGRAL SAFETY COMPONENT REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING 8 0 REPLACEMENTS COMPONENTS REF NO PART NO DESCRIPTION 1 W725 0039 NATURAL GAS VALVE 1...

Page 23: ...ON OFF REMOTE 33 F52 THERMOSTATIC REMOTE 34 GD 660 REMOTE WALL SWITCH WITH 20 WIRE 35 GI823KT DECORATIVE BRICK PANELS 36 W175 0162 CONVERSION KIT NG LP 36 W175 0192 CONVERSION KIT LP NG 37 GIZBP6 3 3...

Page 24: ...24 W415 0224 G 02 28 11 7 6 16 5 27 28 21 35 41 1 24 2 14 10 11 12 13 47 45 38 40 41 3...

Page 25: ...burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals if main burner lights replace swi...

Page 26: ...ames are very aggressive Door is ajar Ensure the mechanical means of securing the door is providing a tight seal Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has...

Page 27: ...ftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused by mechan...

Page 28: ...28 W415 0224 G 02 28 11 11 0 SERVICE HISTORY 43 1...

Reviews: