Continental Fireplaces CDIZC - N Installation And Operating Instructions Manual Download Page 15

15

W415-0224 / G / 04.05.11

97.1

Remove the backing of the logo supplied and place on the glass viewing door, 
as indicated.

½"

½"

LOGO

4.5 LOGO 

PLACEMENT

4.6  ALUMINUM EXTRUSION TRIM KIT INSTALLATION

In order to close off the fi replace opening or if the opening is larger than the 3- or 4-sided aluminum extrusion 
trim kits, it is recommended to reduce the opening using a noncombustible material such as ceramic tile, 
marble, etc or the 

GIZBP6-3

 or 

GIZBP6-4

 backer plate kits. The outside edge of the backer plate is fi nished 

off with gold trim included in each kit. A deluxe fl ashing kit complete with marquis trim may also be used to 
complete the installation. These fl ashing and trim combinations are available in 6 and 9 inch widths as well 
as many fi nishes to accent any room decor. Mounting brackets, 

GIZBRKT

, are required to install the deluxe 

fl ashing. Detailed installation instructions are included with each kit.
If this appliance is being installed into an existing wood burning, zero clearance fi replace, then be aware of this 
precaution: 

Any circulation air opening may be covered (with noncombustible material) but not sealed!

The appliance can be equipped with either a 3- or 4-sided trim kit to fi nish off the 
fi replace opening. Slide the trim assembly over the keyholes (2 per side) and 
drop into place. 

If installing the optional 3- or 4-sided backer plate (GIZBP6-3

 

or 

GIZBP6-4), it must be hung prior to the trim kit installation using the same 

keyholes. 

To adjust the trim: If the mitre is out of alignment, open each side and loosen the 
two screws at either side trim hinge. Slide the trim up or down to adjust and re-
tighten screws. 

There is also a very slight in/out adjustment that can be made.

Note: Since the side panels open and close, to access the controls, a gap is 
necessary at the mitre joint.

The top trim piece has an adjustable securing bracket which enables the trim to be 
secured to the fi rebox shell.

FIRE VIEWING DOOR

VALVE 

CONTROL 

DOOR

LOOSEN 
SCREWS

SLIDE TO 
ADJUST

Summary of Contents for CDIZC - N

Page 1: ...r gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier This appliance may be installed as an OEM installation in man...

Page 2: ...REMOVAL AND INSTALLATION 13 4 3 LOG PLACEMENT 14 4 4 GLOWING EMBERS 14 4 5 LOGO PLACEMENT 15 4 6 ALUMINUM EXTRUSION TRIM KIT INSTALLATION 15 5 0 OPERATION 16 6 0 ADJUSTMENTS 17 6 1 PILOT BURNER ADJUST...

Page 3: ...IMNEY CONNECTION section Trim see ALUMINUM EXTRUSION TRIM KIT INSTALLATION section Door see DOOR REMOVAL AND INSTALLATION section Rating Plate see RATING PLATE INFORMATION section Logs see LOG PLACEME...

Page 4: ...tive that the control compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system should be inspected before...

Page 5: ...h the appliance is to be installed is HEIGHT 14 5 WIDTH 25 DEPTH 11 The minimum allowable chimney flue size is 6 round 2 2 MINIMUM OPENING 44 7 8 36 1 2 4 SIDED BACKER PLATE ALUMINUM TRIM 36 15 1 2 25...

Page 6: ...n where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood flooring...

Page 7: ...er Column When the appliance is installed at elevations above 4 500ft and in the absence of specific recommendations from the local authority having jurisdiction the certified high altitude input rati...

Page 8: ...IL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT ELECTRICAL RATING CLASS 115V 1 5AMP 60HZ THE APPLIANCE MUST BE VENTED USIN...

Page 9: ...NON COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES USE WOLF STEEL LTD SUPPORT RING ASSEMBLY W010 0370 OR EQUIVALENT NON COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARA...

Page 10: ...chimney with screws and plugs not supplied C INSIDE Attach and secure the flex liners to the vent connection assembly using the same procedure as before ensuring that the marked exhaust liner is attac...

Page 11: ...use open flame WARNING RISK OF FIRE EXPLOSION OR ASPHYXIATION ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING...

Page 12: ...ANY NON COMBUSTIBLE MATERIALS SUCH AS BRICK MARBLE GRANITE ETC PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED DO NOT STRIKE SLAM OR SCRATCH GLASS DO NOT OPERATE A...

Page 13: ...ERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS LOUVRES OPENINGS OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS BEFORE DOOR...

Page 14: ...heat activated curing process A Place the rear log 1 onto the two log supports and against the air intake pipe B Position logs 2 and 3 against the grate posts and line up the studs located on the burn...

Page 15: ...cluded with each kit If this appliance is being installed into an existing wood burning zero clearance fireplace then be aware of this precaution Any circulation air opening may be covered with noncom...

Page 16: ...ERATION FOR YOURSAFETY READBEFOREOPERATING POUR VOTRE SECURITE LIRE AVANT DE FAIRE FONCTIONNER WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY D...

Page 17: ...ADINGS TIGHTEN SCREWS FIRMLY TO SEAL DO NOT OVER TORQUE LEAK TEST 39 6 PILOT BURNER THERMOCOUPLE THERMOPILE P I L O T PILOT SCREW A B 6 2 VENTURI ADJUSTMENT This appliance has an air shutter that has...

Page 18: ...FLAME MUST ENVELOPE UPPER 3 8 TO 1 2 OF THERMOCOUPLE THERMOPILE 6 3 FLAME CHARACTERISTICS 6 4 RESTRICTING VERTICAL VENTS Some vent configurations may display a very active flame If this appearance is...

Page 19: ...nd bottom of the door is not broken or missing Replace if necessary 8 If for any reason the vent air intake system is disassembled re install and re seal per the instructions provided for the initial...

Page 20: ...the gasket holding the glass in place Careful not to break the glass GLASS GASKET DOOR FRAME GLASS RETAINER WARNING DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED CAR...

Page 21: ...k on Because the blower is thermally activated when turned on it will automatically start approximately 5 15 minutes after lighting the appliance and will run for approximately 30 45 minutes after the...

Page 22: ...T IS AN INTEGRAL SAFETY COMPONENT REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING 8 0 REPLACEMENTS COMPONENTS REF NO PART NO DESCRIPTION 1 W725 0039 NATURAL GAS VALVE 1...

Page 23: ...ON OFF REMOTE 33 F52 THERMOSTATIC REMOTE 34 GD 660 REMOTE WALL SWITCH WITH 20 WIRE 35 GI823KT DECORATIVE BRICK PANELS 36 W175 0162 CONVERSION KIT NG LP 36 W175 0192 CONVERSION KIT LP NG 37 GIZBP6 3 3...

Page 24: ...24 W415 0224 G 02 28 11 7 6 16 5 27 28 21 35 41 1 24 2 14 10 11 12 13 47 45 38 40 41 3...

Page 25: ...burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals if main burner lights replace swi...

Page 26: ...ames are very aggressive Door is ajar Ensure the mechanical means of securing the door is providing a tight seal Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has...

Page 27: ...ftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused by mechan...

Page 28: ...28 W415 0224 G 02 28 11 11 0 SERVICE HISTORY 43 1...

Reviews: