Continental Fireplaces CDIZC - N Installation And Operating Instructions Manual Download Page 22

22

W415-0224 / G / 02.28.11

Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally 
all parts can be ordered through your Authorized dealer / distributor. 

FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE 
REQUIRED TO HONOUR THE CLAIM.

When ordering replacement parts always give the following information:
• 

Model & Serial Number of appliance

• 

Installation date of appliance

• Part 

number

• 

Description of part

• Finish

* IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER INFORMATION, CONTACT YOUR 
AUTHORIZED DEALER.

41.2

FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE 

ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY 

DAMAGE OR PERSONAL INJURY.

** THIS IS A FAST ACTING THERMOCOUPLE. IT IS AN INTEGRAL SAFETY COMPONENT. REPLACE ONLY WITH 

A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.

!

WARNING

8.0 REPLACEMENTS

COMPONENTS

REF NO.

PART NO.

DESCRIPTION

1

W725-0039

NATURAL GAS VALVE

1

W725-0040

PROPANE GAS VALVE

2

W100-0128

BURNER

3

W456-0042

#42 NATURAL GAS BURNER ORIFICE

3

W456-0053

#53 PROPANE GAS BURNER ORIFICE

4*

W357-0001

PIEZO IGNITER

5

W680-0004

THERMOPILE

6

W680-0005

THERMOCOUPLE**

7

W010-0801

NATURAL GAS PILOT ASSEMBLY

7

W010-0800

PROPANE GAS PILOT ASSEMBLY

8*

W690-0002

THERMAL SENSING SWITCH

9*

W660-0009

BURNER ON/OFF SWITCH

10

W135-0136

REAR LOG 

11

W135-0138

RIGHT LOG 

12

W135-0137

LEFT LOG 

13

W135-0139

CENTER LOG 

14

GL-631

LOG SET

15*

W361-0016

GLOWING EMBERS

16

W455-0069

NATURAL GAS PILOT INJECTOR

16

W455-0068

PROPANE GAS PILOT INJECTOR

17*

W385-0430

CONTINENTAL LOGO

18*

KB-35

VARIABLE SPEED SWITCH

19*

W380-0002

VARIABLE SPEED SWTICH KNOB

20*

W010-0804

GLASS W/ GASKET

21

W010-0802

DOOR, GLASS & GASKET ASSEMBLY

22*

W225-0095

DOOR FRAME

23*

W573-0007

HIGH TEMPERATURE SEALANT

Summary of Contents for CDIZC - N

Page 1: ...r gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier This appliance may be installed as an OEM installation in man...

Page 2: ...REMOVAL AND INSTALLATION 13 4 3 LOG PLACEMENT 14 4 4 GLOWING EMBERS 14 4 5 LOGO PLACEMENT 15 4 6 ALUMINUM EXTRUSION TRIM KIT INSTALLATION 15 5 0 OPERATION 16 6 0 ADJUSTMENTS 17 6 1 PILOT BURNER ADJUST...

Page 3: ...IMNEY CONNECTION section Trim see ALUMINUM EXTRUSION TRIM KIT INSTALLATION section Door see DOOR REMOVAL AND INSTALLATION section Rating Plate see RATING PLATE INFORMATION section Logs see LOG PLACEME...

Page 4: ...tive that the control compartments burners and circulating blower and its passageway in the appliance and venting system are kept clean The appliance and its venting system should be inspected before...

Page 5: ...h the appliance is to be installed is HEIGHT 14 5 WIDTH 25 DEPTH 11 The minimum allowable chimney flue size is 6 round 2 2 MINIMUM OPENING 44 7 8 36 1 2 4 SIDED BACKER PLATE ALUMINUM TRIM 36 15 1 2 25...

Page 6: ...n where the vent will pass through the house without cutting a floor or roof joist If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood flooring...

Page 7: ...er Column When the appliance is installed at elevations above 4 500ft and in the absence of specific recommendations from the local authority having jurisdiction the certified high altitude input rati...

Page 8: ...IL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT ELECTRICAL RATING CLASS 115V 1 5AMP 60HZ THE APPLIANCE MUST BE VENTED USIN...

Page 9: ...NON COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM COMBUSTIBLES USE WOLF STEEL LTD SUPPORT RING ASSEMBLY W010 0370 OR EQUIVALENT NON COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARA...

Page 10: ...chimney with screws and plugs not supplied C INSIDE Attach and secure the flex liners to the vent connection assembly using the same procedure as before ensuring that the marked exhaust liner is attac...

Page 11: ...use open flame WARNING RISK OF FIRE EXPLOSION OR ASPHYXIATION ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING...

Page 12: ...ANY NON COMBUSTIBLE MATERIALS SUCH AS BRICK MARBLE GRANITE ETC PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED DO NOT STRIKE SLAM OR SCRATCH GLASS DO NOT OPERATE A...

Page 13: ...ERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS LOUVRES OPENINGS OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS BEFORE DOOR...

Page 14: ...heat activated curing process A Place the rear log 1 onto the two log supports and against the air intake pipe B Position logs 2 and 3 against the grate posts and line up the studs located on the burn...

Page 15: ...cluded with each kit If this appliance is being installed into an existing wood burning zero clearance fireplace then be aware of this precaution Any circulation air opening may be covered with noncom...

Page 16: ...ERATION FOR YOURSAFETY READBEFOREOPERATING POUR VOTRE SECURITE LIRE AVANT DE FAIRE FONCTIONNER WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY D...

Page 17: ...ADINGS TIGHTEN SCREWS FIRMLY TO SEAL DO NOT OVER TORQUE LEAK TEST 39 6 PILOT BURNER THERMOCOUPLE THERMOPILE P I L O T PILOT SCREW A B 6 2 VENTURI ADJUSTMENT This appliance has an air shutter that has...

Page 18: ...FLAME MUST ENVELOPE UPPER 3 8 TO 1 2 OF THERMOCOUPLE THERMOPILE 6 3 FLAME CHARACTERISTICS 6 4 RESTRICTING VERTICAL VENTS Some vent configurations may display a very active flame If this appearance is...

Page 19: ...nd bottom of the door is not broken or missing Replace if necessary 8 If for any reason the vent air intake system is disassembled re install and re seal per the instructions provided for the initial...

Page 20: ...the gasket holding the glass in place Careful not to break the glass GLASS GASKET DOOR FRAME GLASS RETAINER WARNING DO NOT USE SUBSTITUTE MATERIALS GLASS MAY BE HOT DO NOT TOUCH GLASS UNTIL COOLED CAR...

Page 21: ...k on Because the blower is thermally activated when turned on it will automatically start approximately 5 15 minutes after lighting the appliance and will run for approximately 30 45 minutes after the...

Page 22: ...T IS AN INTEGRAL SAFETY COMPONENT REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD WARNING 8 0 REPLACEMENTS COMPONENTS REF NO PART NO DESCRIPTION 1 W725 0039 NATURAL GAS VALVE 1...

Page 23: ...ON OFF REMOTE 33 F52 THERMOSTATIC REMOTE 34 GD 660 REMOTE WALL SWITCH WITH 20 WIRE 35 GI823KT DECORATIVE BRICK PANELS 36 W175 0162 CONVERSION KIT NG LP 36 W175 0192 CONVERSION KIT LP NG 37 GIZBP6 3 3...

Page 24: ...24 W415 0224 G 02 28 11 7 6 16 5 27 28 21 35 41 1 24 2 14 10 11 12 13 47 45 38 40 41 3...

Page 25: ...burning no gas to main burner gas knob is on HI wall switch thermostat is on Thermostat or switch is defective Connect a jumper wire across the wall switch terminals if main burner lights replace swi...

Page 26: ...ames are very aggressive Door is ajar Ensure the mechanical means of securing the door is providing a tight seal Carbon is being deposited on glass logs or combustion chamber surfaces Air shutter has...

Page 27: ...ftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused by mechan...

Page 28: ...28 W415 0224 G 02 28 11 11 0 SERVICE HISTORY 43 1...

Reviews: