W415-2344 / A / 11.12.19
EN
16
4.0 blower replacement
black
white
red
SPEED
CONTROL
SWITCH
BLOWER
THERMAL
SWITCH
FRONT BLOWER ACCESS COVER
REAR BLOWER ACCESS COVER
A.
Turn off the electrical power and the gas
supply to the appliance.
B.
Open the glass door and remove the logs and
fi bre bricks, if installed.
C.
Remove the front blower access cover held on
with 4 screws.
D.
Remove the rear blower access cover.
NOTE:
Check the blower gasket for damage.
Replace if damaged.
E.
Disconnect the two blower wires. Remove the
blower from the mounting plate and replace.
For thermal switch replacement: Remove the
mounting bracket secured to the underside of
the burner base. Remove the thermal switch
from the bracket and replace.
F.
Reconnect the two wires. Re-install the blower
gasket. Reattach the blower mounting plate
and blower access covers. Replace the logs.
Close the fi re viewing door.
G.
Turn the gas supply and electricity back on.
Because the blower is thermally activated,
when turned on, it will automatically start
approximately 5-15 minutes after lighting the
appliance and will run for approximately 30-45
minutes after the appliance has been turned
off. Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower
bearings causing irreparable damage and must
be prevented from coming into contact with
the blower or its compartment. Any damage
resulting from this condition is not covered by
the warranty policy.
THERMAL SWITCH / BRACKET
ASSEMBLY
!
WARNING
• Risk of fire and electrical shock!
• Turn off the gas and electrical power before servicing this appliance.
• Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using
non-listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could
result in a safety hazard and will void the warranty and certification.
• Ensure that the fan’s power cord is not in contact with any surface of the appliance to prevent electrical
shock or fire damage. Do not run the power cord beneath the appliance.
• The wire harness provided in the blower kit is a universal harness. When installed, ensure that any excess
wire is contained, prevent it from making contact with moving or hot objects.