7
W415-1364 / 12.08.14
EN
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE:
The rating plate must remain with the appliance at all time. It must not be removed.
SAMPLE
2.4 RATING PLATE INFORMATION
3.0 VENTING
7.1C
THIS APPLIANCE USES A 4” (102mm) EXHAUST / 7” (178mm) AIR INTAKE VENT PIPE SYSTEM.
Refer to the section applicable to your installation.
For safe and proper operation of the appliance follow the venting instruction exactly. Deviation from the
minimum vertical vent length can create dif
fi
culty in burner start-up and/or carboning. Under extreme
vent con
fi
gurations, allow several minutes (5-15) for the
fl
ame to stabilize after ignition. Although not a
requirement, it is recommended for vent lengths that pass through unheated spaces (attics, garages, crawl
spaces) be insulated with the insulation wrapped in a protective sleeve to minimize condensation. Provide
a means for visually checking the vent connection to the appliance after the appliance is installed. Use a
fi
restop, vent pipe shield or attic insulation shield when penetrating interior walls,
fl
oor or ceiling.
NOTE: If for any reason the vent air intake system is disassembled; reinstall per the instructions
provided for the initial installation.
!
WARNING
RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.
IF VENTING IS INCLUDED WITH SPACERS THE VENT SYSTEM MUST BE SUPPORTED EVERY 3FT
(0.9m) FOR BOTH VERTICAL AND HORIZONTAL RUNS. USE SUPPORTS OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE REQUIRED CLEARANCE FROM
COMBUSTIBLES. USE WOLF STEEL LTD. SUPPORT RING ASSEMBLY W010-0370 OR EQUIVALENT
NON-COMBUSTIBLE STRAPPING TO MAINTAIN THE MINIMUM CLEARANCE TO COMBUSTIBLES
FOR BOTH VERTICAL AND HORIZONTAL RUNS. SPACERS ARE ATTACHED TO THE INNER PIPE AT
PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER PIPE. THIS GAP IS
REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF
EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED. THESE SPACERS MUST NOT BE REMOVED.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
SERIAL NUMBER/NO. DE SERIE:
BGD36CF
FOYER A GAZ VENTILE DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE
MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA
NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR,
SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE,
SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE
L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET
LES COMMUNAUTES, ANSI/NFPA 501A. LORSQU'IL EST INSTALLE AVEC LA TROUSSE POUR
ECRAN GD-565KT, LE FOYER EST CONFORME A LA NORME DE CERTIFICATION DE L'ACG
CR95-006.
POUR UNE UTILISER SEULMENT AVEC BARRIÈRE W565-0178. SUIVEZ LES
INSTRUCTIONS D'INSTALLATION SE TROUVENT DANS LE MANUEL D'INSTALLATION.
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM
AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME
INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR
IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE
USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. WHEN INSTALLED WITH
SCREEN KIT GD-565KT, THE FIREPLACE COMPLIES WITH CGA CERTIFICATION
REQUIREMENT CR95-006.
FOR USE ONLY WITH BARRIER W565-0178. FOLLOW THE
INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
BGD36CFNTR
BCDV36CFNTR
MODEL
BGD36CFPTR
BCDV36CFPTR
0-4500FT (0-1370m)
ALTITUDE / ELEVATION
0-4500FT (0-1370m)
17,000 BTU/h
INPUT / ALIMENTATION
17,000 BTU/h
12,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUITE
12,000 BTU/h
59.4% P4 59.4%
MANIFOLD PRESSURE:
3.5" WATER COLUMN
MANIFOLD PRESSURE:
10" WATER COLUMN
PRESSION AU COLLECTEUR:
3.5" D'UNE COLONNE D'EAU
PRESSION AU COLLECTEUR:
10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE:
4.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE:
4.5" D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MINIMALE:
11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE:
7.0" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE:
7.0" D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MAXIMALE:
13" D'UNE COLONNE D'EAU
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS UNIT ONLY.
WARNING: THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE.
REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH
THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE
APPLIANCE.
DECORATIVE PRODUCT:
NOT FOR USE AS A HEATING APPLIANCE
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
TOP/ DESSUS
0
RECESSED DEPTH / PROFONDEUR D'ENCASTRE
17.25"
FLOOR / PLANCHER
0
VENT SIDES / COTES DE L'EVENT
1"
SIDES / COTES
0
VENT TOP / EVENT SUPERIEUR
2"
BACK / ARRIERE
0
VENT BOTTOM / EVENT INFERIEUR
1"
MANTEL / MANTEAU
12" *
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE
INSTRUCTION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL
D'INSTRUCTION POUR DES EXTENSIONS PLUS GRANDES.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS
D'EVACUATION MINIMALE ET MAXIMALE.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION
RAPIDE. REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE
WOLF STEEL LTÉE. N’AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER
EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET
APPAREIL PAR LE FABRICANT.
PRODUIT DÉCORATIF:
NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE
OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND
RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A
NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER
L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ550-KT, GD65
9700539 (WSL)
4001657 (NGZ)
4001658
(NAC)
4001659
(WUSA)
W385-1980