30
W415-1364 / 12.08.14
EN
5.9 OPTIONAL WALL SWITCH EXCLUDING BCDV36CFG
50.1A
For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient
location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The
recommended maximum lead length depends on wire size:
WIRE SIZE
MAX. LENGTH
14 gauge (1.8mm)
100 feet (30.5m)
16 gauge (1.5mm)
60 feet (18.3m)
18 gauge (1.2mm)
40 feet (12.2m)
Disconnect the existing wires from terminals 1 and 3 (from the
ON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.
3
1
2
!
WARNING
DO NOT CONNECT EITHER THE WALL SWITCH, THERMOSTAT OR GAS VALVE DIRECTLY TO 110
VOLT ELECTRICITY.