4-4
Operator Panel and Indicators
3. Wait LED
The Wait LED lights when the scanner power is turned on, and stays
on during the internal diagnostic and stabilization phase. Keyboard
input is prevented during this time.
The Wait indicator reveals the status of the scanner’s self-adjustment
procedure, which consists of both stitching and light profile
adjustment. If the scanner does not self adjust the stitching and light
profiles may change over time due to thermal changes in the scanner.
The Wait indicator works in the following way:
•
When the
Wait Indicator
is off, the self-adjustment is up-to-
date, and the scanner is ready to scan.
•
When the
Wait Indicator
is on, the scanner is warming-up or
re-adjusting; a scan may be issued, but quality may be
compromised (when adjusting is completed, the
Wait Indicator
turns off). To allow the scanner to self adjust do not (re)move
original or change
Original Pressure Platen
position while the
Wait Indicator is on.
•
When the
Wait Indicator
is flashing (and the
Diagnostics
Indicator
is off) re-adjusting is needed, but not possible; any
original in the scanner should be removed, and
Original
Pressure Platen
should be returned to the normal position
(also in this situation a scan may be issued, but the quality will
be compromised). When adjusting is again possible, the
Wait
Indicator
stops flashing, but continues to be on until the self-
adjust is complete.
•
The
Wait Indicator
is on during basic calibration to indicate
that the original should not be (re)moved during this
procedure (for the same reason the scanner keyboard is
disabled during basic calibration).