D-7
Appendix D --- Error codes
Error code
100-50269
Keypad
Error code
ERR_SU (12)
Level
Support
Correctable
Description
IMx, Flash error
Potential failed comp.
IMx, SUx
Corrective Action.
■
Interface board (IMx).
■
Main controller board (SUx).
Error code
100-50270
Keypad
Error code
ERR_SU (12)
Level
Support
Correctable
Description
IMx, RAM error
Potential failed comp.
IMx, SUx
Corrective Action.
■
Interface board (IMx).
■
Main controller board (SUx).
Error code
100-50271
Keypad
Error code
ERR_SU (12)
Level
Support
Correctable
Description
SUx, Scanner has no MAC address
Potential failed comp.
SUx
Corrective Action.
■
Main controller board (SUx).
Error code
100-50705
Keypad
Error code
None
Level
User
Correctable
Description
Scanner serial cannot be changed while activated.
Potential failed comp.
User
Corrective Action.
■
User interaction.
Error code
100-50218
Keypad
Error code
None
Level
RD
Correctable
Description
Data never arrives in the Image
Potential failed comp.
Buffer, Firmware
Corrective Action.
■
Firmware.
Summary of Contents for SD 3600 series
Page 1: ...Technical Service Guide for SD3600 FSM TSG 001 1 3 ...
Page 6: ...vi ...
Page 7: ...Introduction ...
Page 10: ...1 4 Introduction ...
Page 11: ...Design Design ...
Page 14: ...2 8 Design Wiring Diagram ...
Page 18: ...2 12 Design ...
Page 19: ...Troubleshooting Troubleshooting ...
Page 25: ...Part replacement ...
Page 28: ...4 10 Part replacement Identifying parts ...
Page 43: ...Appendix A WIDEsystem service ...
Page 54: ...A 12 Appendix A ...
Page 55: ...Appendix B Firmware download ...
Page 60: ...B 6 Appendix B ...
Page 61: ...Appendix C Scanner Terms Appendix C Scanner Terms ...
Page 69: ...Appendix D Error codes Appendix D Error codes ...
Page 76: ...D 8 Appendix D Error codes ...
Page 77: ...Appendix E Scanner License Appendix E Scanner License ...