Evora-Flex5R
- SPOT/FROST moving head with Philips
©
MSD PLATINUM 5R lamp
Page 5
English
1 -
Remove the 3 panel screws (labeled A, B, and C)
2 -
Slowly pull it backwards. Disconnect the two wires connected to the lamp. Squeeze the lamp holding clips together and lift the
holder.
3 -
Insert the new lamp. Please make sure not to touch the lamp with your bare fingers as it will damage it. A fabric is supplied
with the lamp to manipulate it safely. Assurez vous que la lampe soit dans la bonne position, the connection lugs must be on the
left of the lamp.
4 -
Reassemble the fixation system and reconnect the wires. Put the panel back.
The Evora-Flex5R device uses this lamp : PLATINUM 5R
©
Philips™
This lamp cannot be hot started. Once turned off, please wait at least 10 minutes before turning it back on.
This unit was designed to use a PHILIPS
™
PLATINUM 5R lamp.
The use of any other lamp voids the warranty.
Any damaged or disformed lamp must be
replaced.
For your safety and the life length of the unit the Philips® Platinum 5R Discharge lamp has its lifetime limited to
2,000 hours.
Because of the nature of the extreme heat associated with the Platinum 5R lamp and the tight nature of the internal
optical system it is imperative that the lamp be replaced every 2000 hours. This is done to protect the internal
optical system as well as prevent accidental lamp explosion, which could lead to hot glass particles falling from the fixture.
Failure to change the lamp within 300 hours of operation will result in automatic shut down of the fixture’s electronics.
At 2000 hours the display will begin to flash “Replace The Lamp” and the lamp will flicker for the first five minutes of operation.
At this point the lamp has reached the maximum rated life and should be replaced immediately. The fixture will continue to
operate for an additional 300 hours, however the “Replace the Lamp” warning will continue to flash in the display. Keep in mind
that the flicker protection circuitry will only work for about 300 hours (lamp clock life of 2000-2300 hours). After 2300 hours the
fixture will no longer respond to DMX commands and immediately enter a hibernation mode that will electronically discontinue
all fixture functionality with the exception of a few menu commands. The fixture will continue to enter hibernation mode until the
lamp is replaced and the lamp clock has been reset. (Menu : Clear Lamp Time).
5 - Replacing the lamp
Please unplug the device and wait at let it
cool down for at least 1 hour before trying
to replace the lamp.