The Evora-Flex5R moving head includes 3 preset DMX modes : 
The Basic mode features 21 channels, the Standard mode features 23 channels and the Expert mode features 34 
channels.
The following chart indicates DMX values of each channels.
Note : St = Standard, Ba = Basique et Ex = Expert.

8 - Dmx channels and their functions

Modes / Channels

DMX values

Functions and effects

St

Ba

Ex

1

1

1

8-bit PAN movement

000 - 255

PAN movement

2

2

16-bit PAN movement

000 - 255

Very precise PAN movement settings

3

2

3

TILT movement

000 - 255

TILT movement

4

4

16-bit TILT movement

000 - 255

Very precise TILT movement settings

5

3

5

PAN/TILT movements speed and reaction

000 - 225

Fast to slow speed settings

226 - 235

Black out during movements

236 - 245

Black-Out during wheels rotation

246 - 255

No function

6

4

6

Shutter et Strobe

000 - 031

Shutter closed

032 - 063

No action, shutter open

064 - 095

Slow to fast strobe

096 - 127

No action, shutter open

128 - 159

Slow to fast pulse effect

160 - 191

No action, shutter open

192 - 223

Slow to fast random strobe

224 - 255

No action, shutter open

7

5

7

Dimmer

000 - 255

Intensity: 0 - 100%

8

16-bit dimmer

000 - 255

Very precise intensity settings

8

6

9

Couleur Cyan

000 - 255

Cyan (000 : White / 255 - Cyan 100%)

10

16-bit Cyan

000 - 255

Very precise Cyan colour settings

9

7

11

Magenta

000 - 255

Magenta (000 : White / 255 - Magenta 100%)

12

16-bit Magenta

000 - 255

Very precise Magenta colour settings

10

8

13

Yellow

000 - 255

Yellow (000 : White / 255 - Yellow 100%)

14

Couleur Yellow 16 bits

000 - 255

Very precise Yellow colour settings

Summary of Contents for Evora Flex5R

Page 1: ...USER GUIDE 10297 1 January 2015 version SPOT FROST MOVING HEAD WITH PHILIPS MSD PLATINUM 5R LAMP Evora F l e x 5 R...

Page 2: ...wash this product 13 Long periods of non use Disconnect the unit s main power during long periods of non use 14 Liquids or objects penetration Do not let any object penetrate this product as it may re...

Page 3: ...r 0 100 Adjustable focus 0 100 Adjustable zoom 10 42 Control Standard DMX 512 21 23 or 34 DMX channels 3 modes Basic Standard or Expert Assignable patch to every channel 7 built in programs accessible...

Page 4: ...owse through menus and change values 7 ENTER button Selects functions and saves changes 8 Navigation button Allows you to browse through menus and change values 9 Transport handle 10 MODE ESC button E...

Page 5: ...t nature of the internal optical system it is imperative that the lamp be replaced every 2000 hours This is done to protect the internal optical system as well as prevent accidental lamp explosion whi...

Page 6: ...the channel number on which the unit receives an incoming DMX signal sent by the DMX remote control The DMX addressing can be performed by programming the channel number via the display located on th...

Page 7: ...browsing through menus values in blue are values currently in use When entering a new value it will be written in red until you save changes by pressing ENTER 7 1 FUNCTION Submenus Values Description...

Page 8: ...ast Run Time The password is 038 Clean Last Run Allows you to reset the Last Run Time Lamp Time Password Password allowing you to reset the overall lamp running time Lamp Hours The password is 038 Cle...

Page 9: ...rse ON OFF Reverses PAN movements Tilt Reverse ON OFF Reverses TILT movements Pan Degree Pan 540 Pan 630 Determine the PAN movement range Pan540 540 rotation 1 5 turn Pan630 630 rotation 1 75 turn Fee...

Page 10: ...High Maximum fan speed Low Decreases cooling speed This is especially useful to reduce the noise when an installation requires silent devices Display setting Shutoff time 02 60m 05m Timer after which...

Page 11: ...Description Test Channel AUTO PAN etc Tests each function individually Manual Control AUTO XXX PAN XXX etc Controls each function manually Calibration Password Password to unlock calibration 050 PAN...

Page 12: ...Program 1 10 Program 3 Allows you to assign one of the 10 built in programs to each Auto Pro Part X Edit Program Program 1 Program 2 Program 10 Pro Test Step 01 64 Allows you to select the scenes ass...

Page 13: ...You can store up to 250 scenes Indicate the number of scenes you want to save precising the opening and ending scenes The opening scene selection uses the left and right arrow buttons The ending scene...

Page 14: ...TILT movements speed and reaction 000 225 Fast to slow speed settings 226 235 Black out during movements 236 245 Black Out during wheels rotation 246 255 No function 6 4 6 Shutter et Strobe 000 031 Sh...

Page 15: ...Rotating gobo 3 040 049 Rotating gobo 4 050 059 Rotating gobo 5 060 069 Rotating gobo 6 070 079 Rotating gobo 7 080 089 Rotating gobo 8 090 104 Rotating gobo 1 shake effect 105 119 Rotating gobo 2 sha...

Page 16: ...162 168 Gobo 7 shake effect 169 175 Gobo 8 shake effect 176 182 Gobo 9 shake effect 183 189 Gobo 10 shake effect 190 196 Gobo 11 shake effect 197 203 Gobo 12 shake effect 204 210 Gobo 13 shake effect...

Page 17: ...cise zoom settings 19 17 29 Iris 000 191 Max diameter to min diameter 192 223 Pulse closing effect from slow to fast 224 255 Pulse opening effect from fast to slow 30 16 bit iris 000 255 Very precise...

Page 18: ...ment built in programs and resets 000 019 Regular colour changes 020 029 Linear colour wheel can create half colours 030 039 Linear gobo and color wheels can create half colours gobos 040 059 Lamp on...

Page 19: ...have various origins Sensors are used to set the motors in their default position Either the magnetic sensors are defective or the magnets have been displaced Problems might also come from a defective...

Page 20: ...s to modifications without prior notice That is why technical specifications and the products physical configuration might differ from the illustrations Make sure you get the latest news and updates a...

Reviews: