background image

  Safety Precautions 

 

CPS-MC341-DS2-111, CPS-MC341-DS2-911 Reference Manual (Hardware) 

  20 

 

3.

 

Battery handling and the storage in EU 

signatory 

This symbol mark is for EU countries only. 
This symbol mark is according to the directive 2006/66/EC Article 20 Information for end-users and 
Annex II. 

 

 

 

 

This symbol mark means that batteries and/or accumulators, at their end-of-life, should be disposed 
separately from the household waste. 
If a chemical symbol is printed beneath the symbol mark shown above, it indicates that the battery 
or accumulator contains a heavy metal at a certain concentration. 
The concentration standard is indicated below:   

Hg: mercury (0.0005%), Cd: cadmium (0.002%), Pb: lead (0.004%) 

These ingredients may cause hazardous conditions for human and the global 
Refer to the appendix for the specification as well as how to remove and dispose of the battery. 

 

Summary of Contents for CPS-MC341-DS2-111

Page 1: ...igital Input Output Module CPS MC341 DS2 111 CPS MC341 DS2 911 Introduction 4 Safety Precautions 12 Product Nomenclature and Function 21 Setup 35 Installation 41 Appendix 61 Optional Products 71 Custo...

Page 2: ...3 Battery handling and the storage in EU signatory 20 Product Nomenclature and Function 21 1 Nomenclature of Product Components 22 2 Description of Product Components 23 1 Power Connector 23 2 Debug...

Page 3: ...LAN 50 3 RS 422A 485 51 4 CAN 56 5 Digital Input 57 6 Digital Output 58 Appendix 61 1 Specifications 62 1 Specifications 62 2 Power Requirements 65 2 Physical Dimensions 66 1 Product 66 3 The Details...

Page 4: ...4 Introduction This section provides necessary information of the product such as the outline bundled items and manuals before actual use...

Page 5: ...ROSYS WEB Setting Download from the Contec website PDF Read the Followings as Necessary Name Purpose Contents How to get CONPROSYS Cloud Data Service 2 CDS2 Manual Read this to understand the outline...

Page 6: ...t using the product visit our website to check the firmware version and update to the latest one if necessary Updating firmware to the latest version will resolve troubles and stabilize the operation...

Page 7: ...and the CPS MC341 DS2 911 contains one battery for RTC within It is equipped with the ARM Cortex A8 processor 600MHz and the 512MB DDR3 SDRAM system memory On board NOR FLASH is utilized for a booting...

Page 8: ...lowing interfaces With the CONPROSYS series data collected from various types of facilities can be managed centrally LAN SD Card Slot USB Digital Input Digital Output Analog Input Current Analog Outpu...

Page 9: ...en the digital input output and CPU as well as between CAN and CPU can block electrical noise flow Moreover the surge protection elements are used for signal line and on top of that the RS 422A 485 is...

Page 10: ...through a Web browser On the monitoring screen the standard GUI parts graphic slider button etc can be freely arranged All operations including monitoring layout making relations with I O information...

Page 11: ...r Product 1 1 Product Guide 1 Warranty Certificate 1 Serial Number Label 1 3 pin Connector 1 Power 5 pin Connector 1 RS 422A 485 10 pin Connector 2 Digital 1 One of the followings CPS MC341 DS2 111 CP...

Page 12: ...12 Safety Precautions Understand the following definitions and precautions to use the product safely Never fail to read them before using the product...

Page 13: ...in minor or moderate injury or in property damage Informations de s curit Ce document contient des informations relatives la s curit sous utilisation des symboles suivant afin d viter tout accident r...

Page 14: ...reliability Do not use the product in such applications If using the product in applications where safety is critical such as in railways automotive or disaster prevention or security systems please c...

Page 15: ...g the power cables immediately and contact your retailer To connect with peripherals use a grounded shielded cable To clean the product wipe it gently with a soft cloth dampened with either water or m...

Page 16: ...ou une d faillance Ne pas mettre le dispositif en contact avec des substances trang res particules m talliques substances inflammables liquides etc Faute de quoi le contact peut provoquer un incendie...

Page 17: ...produit Pour une utilisation dans un tel environnement installer par exemple un panneau de contr le l preuve de la poussi re viter d utiliser le produit dans des endroits susceptibles aux chocs ou au...

Page 18: ...ionnement du produit sans interruption s assurer de lire le manuel du site Web CONTEC et d assimiler le contenu Lorsque le produit est utilis un endroit influenc par une surintensit ou une surtension...

Page 19: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in...

Page 20: ...and or accumulators at their end of life should be disposed separately from the household waste If a chemical symbol is printed beneath the symbol mark shown above it indicates that the battery or acc...

Page 21: ...21 Product Nomenclature and Function This section describes product component names and their functions pin assignment of each connector...

Page 22: ...6 LED Indicator This indicates status of the product 7 Reset Switch This resets the product 8 Shut Down Switch This shuts down the product 9 DIP Switch This is used for system setup and RS 422A 485 se...

Page 23: ...package to connect to external power Connector type DEGSON 15EDGK 3 5 03P 14 1000AH or equivalent The type of connectors in the package differs depending on the period of manufacturing To check the su...

Page 24: ...as two ports on kernel With this product only CAN0 can be used Pin Assignment Pin No Signal Name Description 1 N C This pin is left unconnected 2 CAN A_L Signal low 3 CAN A_GND Signal ground 4 Reserv...

Page 25: ...T2 Red Refer to the Reference Manual Software TX COM A Yellow Flashing It flashes upon sending data by the RS 422A 485 OFF It indicates there is no data transmission by RS 422A 485 RX COM A Yellow Fla...

Page 26: ...connection state of TX and RX Short Half Duplex OFF Internal connection state of TX and RX Open Full Duplex 4 ON Internal connection state of TX and RX Short Half Duplex OFF Internal connection state...

Page 27: ...1 Reference Manual Hardware 27 DIP Switch Bit No ON OFF Description 1 ON SW Number 1 2 ON Enable the Terminator Terminator value 120 OFF Disable the Terminator 2 ON SW Number 1 2 ON Enable the Termina...

Page 28: ...n data Output 2 TX Transmission data Output 3 RX Reception data Input 4 N C This pin is left unconnected 5 N C This pin is left unconnected 6 RX Reception data Input 7 N C This pin is left unconnected...

Page 29: ...ucts If a large amount of data or high speed response is requested an external switching HUB will be required ATTENTION Le mode avec concentrateur de commutation du produit peut tre plus lent que d au...

Page 30: ...the output signals of channel 6 It connects the input signals from the other devices 4 DO5 This indicates the output signals of channel 5 It connects the input signals from the other devices 5 DO4 Th...

Page 31: ...This indicates the input signals of channel 6 It connects the output signals from the other devices 4 DI5 This indicates the input signals of channel 5 It connects the output signals from the other de...

Page 32: ...e package to connect to external power Connector type DEGSON 15EDGK 3 5 05P 14 1000AH or equivalent The type of connectors in the package differs depending on the period of manufacturing To check the...

Page 33: ...he signal level remains the same over the digital filter setting time sampling four times the digital filter recognizes that signals as normal and changes the filter output signal level When there is...

Page 34: ...msec 10 0Ah 128 sec The table below lists the relation between digital filter time and setting data Digital Filter Time sec 2n 8x106 n Setting Data 0 20 CAUTION The digital filter applies to all input...

Page 35: ...35 Setup This section describes how to set switches and an antenna that are necessary to operate the product...

Page 36: ...nator setup Set the terminators on or off in accordance with the device which you are communicating with The DIP switch SW2 sets the terminator The terminators on the product are 100 resistors If you...

Page 37: ...m Reservation Always OFF 2 System Reservation Always OFF 3 System Reservation Always OFF 4 System Reservation Always OFF 5 System Reservation Always OFF 6 System Reservation Always OFF Full Duplex Swi...

Page 38: ...Internal connection state of TX and RX Open Full Duplex 4 ON Internal connection state of TX and RX Short Half Duplex OFF Internal connection state of TX and RX Open Full Duplex SW1 1 System Reservati...

Page 39: ...f the cover Card cover is attached to the product upon shipping 2 Slide the card cover to remove it 3 With the chipped edge of the SD card is in the position shown below insert the card all the way in...

Page 40: ...Setup CPS MC341 DS2 111 CPS MC341 DS2 911 Reference Manual Hardware 40 5 Fasten with a screw Reverse the procedure described in the Insert SD card to remove the card...

Page 41: ...41 Installation This section describes how to mount the product on a DIN rail or on the wall and to connect to an external device with a cable...

Page 42: ...Install the product in the orientations shown below 0 C Other orientations may cause problems such as malfunctions due to inadequate heat dissipation DIN rail Mounting Wall Mounting Operating ambient...

Page 43: ...erature is within the specified range an operational malfunction may occur if there is other device generating high heat the radiation will influence the product to increase its temperature Do not ins...

Page 44: ...ure interne est r gl e par un appareil comme un climatiseur Une utilisation sur une p riode prolong e peut accro tre la temp rature et mener une d faillance ou d autres probl mes Lors de l utilisation...

Page 45: ...lock the product on the DIN rail How to Remove 1 Pull down the hooks to unlock If the hooks are stuck use a slotted screwdriver to unlock 2 1 With the hooks unlocked pull the lower part of the produc...

Page 46: ...nd set the product CAUTION Tightening torque should be carefully controlled according to the wall on which you are installing to Installing onto the wall may not satisfy the UL standard certification...

Page 47: ...t of a cable and insert it to the opening 2 After the insertion secure the stripped part by turning screws with a slotted driver to prevent it from disconnecting CAUTION Removing the connector plug by...

Page 48: ...teur pour retirer la fiche vous risquez de briser le fil Saisissez toujours le connecteur pour le retirer Le couple de serrage pour le connecteur fourni est indiqu ci dessous DEGSON 0 19 N m PHOENIX C...

Page 49: ...Supply This product is designed to operate at least with 15watt power supply In addition the power supply must fulfill the following requirements Rising time for up to 12 voltage 2 milliseconds up to...

Page 50: ...our le connecteur fourni est indiqu ci dessous DEGSON 0 19 N m PHOENIX CONTACT PTR MESSTECHNIK 0 25 N m D nudez environ 7 mm plus ou moins 0 5 mm de la section gain e du c ble pour le raccorder au con...

Page 51: ...200 600 57 600 900 19 200 1 200 9 600 The cable lengths in the table are not guaranteed for the communication speed The table below lists the maximum communication distances of the terminator resistor...

Page 52: ...ud Rate bps Error 300 0 00 600 0 00 900 0 00 1 200 0 00 2 400 0 00 4 800 0 00 9 600 0 16 14 400 0 16 19 200 0 16 28 800 0 16 38 400 0 16 57 600 0 16 115 200 0 16 Half Duplex Half duplex needs two or m...

Page 53: ...ion of the external device Full Duplex Full duplex needs three or more sets of twisted pair Two sets are for a signal line other free line s is are for the signal ground SG Connect TX and TX RX and RX...

Page 54: ...nd SG CAUTION Removing the connector plug by grasping the cable can break the wire Always grasp the connector to remove it Tightening torque of the supplied connector is described below DEGSON 0 19 N...

Page 55: ...pour le connecteur fourni est indiqu ci dessous DEGSON 0 19 N m PHOENIX CONTACT PTR MESSTECHNIK 0 25 N m Si les c bles blind s sont mal raccord s la mise la terre le blindage pourrait agir comme ante...

Page 56: ...ontroller Area Network needs two or more sets of twisted pair One set is for a signal line other free line s is are for the signal ground SG Connect CAN A_H and CAN A_L to make them as a set of twiste...

Page 57: ...ment Input equivalent circuit Input equivalent circuit of digital input interface unit is shown in Figures below DI connects to a device which can be current driven such as switch or transistor output...

Page 58: ...n assignment Digital Output Circuit DO connects to the device controlled by the current drive such as relay controlling or LED The connection requires an external power supply to deliver current ON OF...

Page 59: ...w DEGSON 0 19 N m PHOENIX CONTACT PTR MESSTECHNIK 0 25 N m If the maximum output current of the external power supply is smaller than the maximum consumption current of the product the abnormal operat...

Page 60: ...z toujours le connecteur pour le retirer Le couple de serrage pour le connecteur fourni est indiqu ci dessous DEGSON 0 19 N m PHOENIX CONTACT PTR MESSTECHNIK 0 25 N m D nudez environ 7 mm plus ou moin...

Page 61: ...61 Appendix This section lists the specifications and the physical dimensions of the product and the details of model name...

Page 62: ...arity Connector 2 piece 3 5mm pitch 5 pin terminal TX TX RX RX SG Applicable wire AWG28 16 LED Transmission Yellow Reception Yellow Switch DIP Switch Full Duplex Half Duplex Terminator ON OFF Surge pr...

Page 63: ...Current 24V 100mA Residual Voltage with Output ON 0 5V or less Output current 50mA 1 0V or less Output current 100mA Response time Within 200 s The number of channels 8 LED DO0 DO7 Yellow Connector 2...

Page 64: ...e 1kV IEC61000 4 4 Level 3 EN61000 4 4 Level 3 Static electricity resistance Touch 4kV IEC61000 4 2 Level 2 EN61000 4 2 Level 2 Air 8kV IEC61000 4 2 Level 3 EN61000 4 2 Level 3 Vibration resistance Sw...

Page 65: ...r OFF time When you use with the CPS PWD 15AW12 01 by CONTEC instantaneous voltage drop allowed time is 20 milliseconds or less ATTENTION Si les fluctuations de la tension d alimentation sont au del d...

Page 66: ...911 Reference Manual Hardware 66 2 Physical Dimensions 1 Product 30 5 20 4 26 3 8 188 78 66 4 170 154 55 4 3 5 LANA 12 24VDC RESET SW1 SD LAN B SHUT CAN A Isolated DOWN mm DO DI SW2 TERM Half Full Ha...

Page 67: ...Description 1 Model MC Gateway Integrated Type Model 2 CPU 3 ARM Cortex A8 3 Memory 4 512M Byte 4 Version 1 The 1st Model 5 Interface D Digital I O S Serial RS 422A 485 6 Numbering of the Interface 2...

Page 68: ...en disposing of the product follow the instruction below and remove the battery 1 Remove the five screws from bottom of the product to remove the cover See the figure below 2 Remove the cover 3 Cut th...

Page 69: ...T 3 5 Green 0 25 N m Connector type Socket MC1 5 3 G 3 5 Green Connector type Plug DEGSON 15EDGK 3 5 03P 14 1000AH Green 0 19 N m Connector type Socket 15EDGRC THR 3 5 03P 13 Black 5pin Connector Conn...

Page 70: ...ert 0 25 N m Type de connecteur broche MC1 5 3 G 3 5 Vert Type de connecteur enfichable DEGSON 15EDGK 3 5 03P 14 1000AH Vert 0 19 N m Type de connecteur broche 15EDGRC THR 3 5 03P 13 Noir Connecteur 5...

Page 71: ...71 Optional Products This section lists optional items that can be used along with the product...

Page 72: ...follows Acquire them as required Product Name Model type Description DIN rail fitting power supply CPS PWD 15AW12 01 Fitting power supply 15W Input 100 240VDC Output 12VDC 1 3A SD Card SD 4GB A SD car...

Page 73: ...73 Customer Support and Inquiry CONTEC provides the following support services for you to use CONTEC products more efficiently and comfortably...

Page 74: ...TEC offers the useful information including product manuals that can be downloaded through the CONTEC website Download https www contec com download You can download updated driver software firmware a...

Page 75: ...75 Index...

Page 76: ...DS2 911 Reference Manual Hardware 76 Revision History MONTH YEAR Summary of Changes December 2015 The First Edition April 2018 Changed the layout of the manual September 2018 Additional information w...

Page 77: ...https www contec com No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD CPS MC341 DS2 111 CPS MC341 DS2 911 Reference Manual...

Reviews: