Installation
—
CPSN-CNT-3201I Reference Manual (Hardware)
—
30
—
Horizontal installation
Make sure to gain proper space between the product and devices that generate heat or exhaust air
so that the ambient temperature stays in the range specified in the environment requirement.
Also, the temperature range in the environment requirements varies depending on the installation
orientation, so check the operating temperature range in
"Specifications (Page 39)"
.
Recommended installation angle
The recommended installation angle for this product is 0°. The temperature specifications of the
product vary between the case when the installation angle is 90° to the left/right and the horizontal
installation is used, therefore check the operating temperature range in
"Specifications (Page 39)"
.
Ambient temperature
The ambient temperature is decided from the multiple measurement points which are a 50mm-
distance from the product.
During the operation, adjust the air current to make certain that the temperatures measured in the
points stay within the specified temperature. (-20 - +60°C)
*As for the vertical installation with an angle of 90° to the right/left or the horizontal Installation, the
ambient temperature should be -20 - +55°C.