![Contec CMS50EW User Manual Download Page 6](http://html1.mh-extra.com/html/contec/cms50ew/cms50ew_user-manual_2655980006.webp)
3
2.
2.
2.
2.
Overview
Overview
Overview
Overview
The pulse oxygen saturation is the percentage of HbO
2
in the total Hb in the blood, so-called the O
2
concentration in the blood. It is an important bio-parameter for the respiration. A number of diseases
relating to respiratory system may cause the decrease of SpO
2
in the blood, furthermore, some other
causes such as the malfunction of human body's self-adjustment, damages during surgery, and the
injuries caused by some medical checkup would also lead to the difficulty of oxygen supply in
human body, and the corresponding symptoms would appear as a consequence, such as vertigo,
impotence, vomit etc. Serious symptoms might bring danger to human's life. Therefore, prompt
information of patients' SpO
2
is of great help for the doctor to discover the potential danger, and is of
great importance in the clinical medical field. The Pulse Oximeter features in small volume, low
power consumption, convenient operation and being portable.It is only necessary for patients to put
one of his fingers into a probe for diagnosis, and a display screen will directly show the measured
value of pulse oxygen saturation with the high veracity and repetition.
2
2
2
2.1
.1
.1
.1....
Features
Features
Features
Features
A.
A.
A.
A.
Operation of the product is simple and convenient.
B.
B.
B.
B.
The product is small in volume, light in weight and convenient in carrying.
C.
C.
C.
C.
Low power consumption
2
2
2
2.2
.2
.2
.2....
Major
Major
Major
Major applications
applications
applications
applications and
and
and
and scope
scope
scope
scope of
of
of
of application
application
application
application
The Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through
finger. The product is suitable for being used in family, hospital, oxygen bar, community healthcare,
physical care in sports (It can be used before or after doing sports, and it is not recommended to use
the device during the process of having sport) and etc.
The problem of overrating would emerge when the patient is suffering from toxicosis which
caused by carbon monoxide, the device is not recommended to be used under this circumstance.
2
2
2
2.3
.3
.3
.3....
Environment
Environment
Environment
Environment requirements
requirements
requirements
requirements
Storage Environment
a) Temperature :-40
℃~
+60
℃
b) Relative humidity :5%
~
95%
c) Atmospheric pressure :500hPa
~
1060hPa
Operating Environment
a) Temperature:10
℃~
40
℃
b) Relative Humidity :3 0%
~
75%
c) Atmospheric pressure:700hPa
~
1060hPa
3
3
3
3....
Principle
Principle
Principle
Principle
Principle of the Oximeter is as follows: An experience formula of data process is established taking
use of Lambert Beer Law according to Spectrum Absorption Characteristics of Reductive
Summary of Contents for CMS50EW