Watchdog Timer
The watchdog timer is started by output of A5 to I/O port address 4002h. A second output of A5 to the
same port within the specified expiration time once again triggers the watchdog timer. If a time-out
occurs, a reset or an interrupt is generated according to the 4004h port setting or an alarm is output
according to the 4004h port setting.
The time-out period can be set between 1 - 255 seconds depending on the timer value setting for the WDT
counter port (4003h).
The watchdog timer stops by reading port 4002h. The alarm-out output is cancelled at the same time.
The alarm out is output from the RAS connector's PO2/WDT (pin 12) and cancelled when reset.
The alarm-out output can be set to BIOS startup by BIOS setup (see Chapter 4), watchdog timer startup,
or watchdog timer time-up.
Specifications
-
Time to be set:
1sec - 255sec
-
Interrupt or reset:
Resets or generates an interrupt at time-up (Port setting).
-
External alarm output:
Photocoupler insulated open-collector output (the output status is set
by software). For more information, see the general-purpose I/O
specifications.
-
I/O addresses:
4000h - 4007h (RAS port)
Summary of Contents for BX710 Series
Page 1: ...IPC Series BOX PC for BX710 Series User s Manual CONTEC CO LTD ...
Page 7: ...vi BX710 series User s Manual ...
Page 18: ...2 System Reference BX710 series User s Manual 11 BX 710P2 AC5 Figure 2 2 BX 710P2 AC5 ...
Page 19: ...2 System Reference 12 BX710 series User s Manual BX 710P4 AC5 Figure 2 3 BX 710P4 AC5 ...
Page 35: ...3 Hardware Setup 28 BX710 series User s Manual ...
Page 61: ...4 BIOS Setup 54 BX710 series User s Manual OnChip IDE Device Figure 4 9 On Chip IDE Device ...
Page 78: ...4 BIOS Setup BX710 series User s Manual 71 Description Choice ...