7. About Hardware
94
AIO-121602LN-USB, AIO-120802LN-USB
Control Signal Timings for Analog Output
Figures 7.8, 7.9, 7.10 and Table 7.4 show the control signal timings for the analog input function.
Figure 7.8. Timing Chart of External Sampling Clock (Analog output)
Figure 7.9. Timing Chart of Sampling Start Control Signal
Figure 7.10. Timing Chart of Sampling Stop Control Signal
Table 7.4. Control Signal Timings
Parameter
Symbol Time
Unit
Delay from external sampling clock to actual start
t
DEC
100
nsec
Settling time
t
WS
1
2
000
nsec
Set up time of sampling start (Rising edge)
t
SRS
100
nsec
Hold time of sampling start (Rising edge)
t
HRS
100
nsec
Set up time of sampling start (Falling edge)
t
SFS
100
nsec
Hold time of sampling start (Falling edge)
t
HFS
100
nsec
Set up time of sampling stop (Rising edge)
t
SRP
100
nsec
Hold time of sampling stop (Rising edge)
t
HRP
100
nsec
Set up time of sampling stop (Falling edge)
t
SFP
100
nsec
Hold time of sampling stop (Falling edge)
t
HFP
100
nsec
The times listed in Table 7.4 are for standard operating conditions.
External Smapling Clock Input
t
DEC
Conversion start
External Smapling Start Trigger Input
t
HRS
t
SRS
t
HFS
t
SFS
External Smapling Stop Trigger Input
t
HRP
t
SRP
t
HFP
t
SFP
CAUTION
Summary of Contents for AIO-120802LN-USB
Page 7: ...vi AIO 121602LN USB AIO 120802LN USB ...
Page 17: ...1 Before Using the Product 10 AIO 121602LN USB AIO 120802LN USB ...
Page 53: ...3 Connection and Installation 46 AIO 121602LN USB AIO 120802LN USB ...
Page 63: ...5 About C LOGGER 56 AIO 121602LN USB AIO 120802LN USB ...
Page 93: ...6 Function 86 AIO 121602LN USB AIO 120802LN USB ...
Page 104: ......