9.5
Counter
The module has in input which can count up to 1000 pulses per second. The module can send messages on a
given threshold. It can also log the counter values for each day.
Configure the following items:
Activate Counter
Name
The unit for the feedback. E.g. Kwh
Puls pro Einhet; E.g. when 100 pulses represent 1Kwh and a feedback or measurement is only wanted
for Kwh and not the actual pulses.
Threshold value; the module sends the configured message every time the threshold is reached
Counter message; the message for the threshold
Clear after send; the counter is cleared after sending the threshold value
Send only the user defined text, this sends only the text defined in the message box, no module name,
IO name and timestamp.
Daily log; Logs the value between midnight and midnight
Clear after Log; Clear the counter after logging the value
To request the actual Counter value send an SMS with the text ‘
CNT
’. The module answers with the counter
value and unit, the value of the current day and the counter start timestamp.
To reset the counter send an SMS with the text ‘
CLRCNT
’.