Conrad 751170 Operating Instructions Manual Download Page 4

Operation

The main unit must be connected with a suitable 9 V/DC power adapter (not 

included) during operation. 4 pieces 1.5 V/DC batteries type AA (not included) 

serve as back-up batteries, in case of a short term mains power failure.

a) Stand-by mode

•  Remove the plastic insulator from the back of the remote control 

before use.

•  After batteries are inserted and the power adapter is plugged, the 

main unit is in stand-by mode.

•  The unit can be changed to other mode by the remote control.

b) Pre-arm mode

•  When the unit is in stand-by mode, press the button (3) to shift to 

pre-arm mode. The buzzer (7) will give one beep sound and green 

status LED (6) will light up for around 20-30 seconds.

•  During pre-arm mode, press the button (3) to return to stand-by 

mode.

•  The alarm will be armed 20 - 30 seconds later.

c) Arm mode

•  After the green status LED (6) turned on for 20 - 30 seconds, the 

alarm will be in arm mode.

•  The green status LED (6) will turn off and the red status LED (8) will 

start flashing.

d) Triggering mode

•  If any intruder or warm object enter the detecting area during arm 

mode, the alarm will be triggered. There is a delay for 10 - 15 

seconds before the alarm goes off.

•  To reset false alarm press the button (3) before the alarm goes off. 

The alarm will return to stand-by mode.

•  Otherwise, a audio warning signal will be generated. The red status 

LED (8) will remain turned on. The alert will last for 40 - 50 seconds 

before the main unit reset automatically to stand-by mode.

•  Press the button (3) to stop the audio warning signal manually.

In case of longer power interruptions and decreasing voltage of the backup 

batteries, the alarm will be activated as followed if the voltage of the backup 

batteries is between 4.0 V and 6.0 V (normal voltage): In activation mode, the 

alarm gets activated and the red LED lights up. After approx. 45 seconds the alarm 

turns off automatically. 

 

Point the remote control transmitter (1) directly towards the remote signal  

receiver (4) within 6m and 30º.
Remote control status LED (2) lights up to indicate signal is transmitting from the 

remote control.

Maintenance and cleaning

Do not use any aggressive cleaning agents, rubbing alcohol or other chemical 

solutions as they can cause damage to the housing and malfunctioning.

•  Never submerge the product in water.
•  There are no components located inside the product you need to maintain. Never open/

dismantle the product.

•  To clean the product, a dry, soft and clean cloth is sufficient. Do not apply too much pressure 

to the housing to prevent scratching.

Disposal

a) Product

Electronic devices are recyclable waste and must not be disposed of in the household 

waste.
At the end of its service life, dispose of the product according to the relevant statutory 

regulations.
Remove any inserted batteries and dispose of them separately from the product.

b) Batteries

You as the end user are required by law (Battery Ordinance) to return all used batteries/

rechargeable batteries. Disposing of them in the household waste is prohibited.

Contaminated (rechargeable) batteries are labelled with this symbol to indicate that 

disposal in the domestic waste is forbidden. The designations for the heavy metals 

involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) 

batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, 

our stores or wherever (rechargeable) batteries are sold. 

You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Operating voltage main unit ................  9 V/DC, 200 mA  via power adapter (not included)
Operating voltage remote control .......  3 x 1,5 V/DC button cell, Type AG13
Power supply backup batteries ...........  4 x 1,5 V/DC batteries, Type AA/Mignon (not included)
Operating temperature .......................  -10 to +50 ºC
Dimensions (W x H x D) .....................  80 x 50 x 120 mm (main unit)
              35 x 20 x 67 mm (remote control)

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau 

(www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, 

or the capture in electronic data processing systems require the prior written approval by the editor. 

Reprinting, also in part, is prohibited. This publication represent the technical status at the time of 

printing.

© Copyright 2014 by Conrad Electronic SE. 

V3_0714_02-HK

Summary of Contents for 751170

Page 1: ...mungsgem e Verwendung Der PIR Alarm ist daf r vorgesehen den Benutzer zu warnen falls eine unbefugte Person innerhalb des Bereiches festgestellt wird der durch den PIR Sensor abgedeckt wird Der Sensor...

Page 2: ...ngerem Stromausfall und abfallender Spannung der St tzbatterien wird der Alarmton bei einer Spannung der St tzbatterien zwischen 4 0 V und 6 0 V normale Spannung wie folgt ausgel st Im Aktivierungsmo...

Page 3: ...l Version 07 14 Item no 751170 Intended use The PIR alarm is intended to alert the resident if an intruder is detected within the area covered by the PIR sensor The sensor detects motion by sensing th...

Page 4: ...Maintenance and cleaning Do not use any aggressive cleaning agents rubbing alcohol or other chemical solutions as they can cause damage to the housing and malfunctioning Never submerge the product in...

Page 5: ...R Le capteur d tecte les mouvements en captant la chaleur corporelle des objets qui se d placent travers sa zone de d tection L alarme a t r gl e avec pr cision afin de minimiser les fausses alertes E...

Page 6: ...nettoyage N utilisez en aucun cas des produits de nettoyage agressifs base d alcool ou toute autre solution chimique car ceux ci pourraient endommager le bo tier et nuire au bon fonctionnement de l a...

Page 7: ...k Het op scherp zetten neutraalstellen van het alarm gaat met de afstandsbediening en de installatie is voorzien van een krachtig 110 dB audio alarm Tijdens de werking dient de hoofdeenheid met een co...

Page 8: ...ugkeren naar de stand by modus In het andere geval wordt een hoorbaar waarschuwingssignaal opgewekt De rode status LED 8 blijft ingeschakeld Het alarm zal gedurende 40 50 seconden aanhouden totdat het...

Reviews: