background image

b) Batteries

•  Correct polarity must be observed while inserting the batteries.
•  Batteries should be removed from the device if it is not used for a long period of 

time to avoid damage through leaking. Leaking or damaged batteries might cause 

acid burns when in contact with skin, therefore use suitable protective gloves to 

handle corrupted batteries.

•  Batteries must be kept out of reach of children. Do not leave batteries lying around, 

as there is risk, that children or pets swallow them.

•  All batteries should be replaced at the same time. Mixing old and new batteries in 

the device can lead to (rechargeable) battery leakage and device damage. 

•  Batteries must not be dismantled, short-circuited or thrown into fire. Never recharge 

non-rechargeable batteries. There is a risk of explosion!

c) Miscellaneous

•  Consult an expert when in doubt about operation, safety or connection of the 

device.

•  Maintenance,  modifications  and  repairs  are  to  be  performed  exclusively  by  an 

expert or at a qualified shop.

•  If you have questions which remain unanswered by these operating instructions, 

contact our technical support service or other technical personnel.

Operating elements

Remote controller Main unit

Mounting bracket

1
2

4

5
6

7

8

3

1 Remote signal transmitter

5 PIR motion detector

2 Remote control status LED 6 Green status LED

3 Mode selection button

7 Buzzer

4 Remote signal receiver

8 Red status LED

Battery replacement

a) Main unit

1.  The batteries are used as back-up power source only. The main unit must be connected 

with a suitable 9 V/DC power adapter (not included) during operation.

2.  Slide out the battery compartment cover located at the back of the main unit.
3.  Insert four AA batteries (Mignon) while observing the correct polarity (“+” = positive;  

“–” = negative).

4.  Close the battery compartment cover.

When the voltage is decreasing, the low battery alarm will be activated as followed: 

When the voltage of the backup batteries is low (e.g. 3.5 to 4.0 V), a beep sounds 

every 6 seconds until the batteries are empty or replaced. The beep only sounds if 

the alarm has not been activated. 

b) Remote control

1.  Unscrew the screw, which located at the back of the remote control to open the remote 

control 

2.  Insert three AG13 button cells while observing the correct polarity (“+” = positive; “–” = 

negative).

3.  Re-assemble the remote control.

Mounting and detection area

The main unit can be mounted on wall with the mounting bracket.
1.  Use the mounting bracket as a template to mark positions on the wall.
2.  Drill two screw holes and insert the included wall plugs.
3.  Affix the mounting bracket on the wall with the provided screws
4.  Attach the mounting bracket to the back of the main unit.
Otherwise, the main unit can be placed on a level and sturdy surface. The 

optimum installation location is 2m from the floor at 15º. The PIR motion 

detector (5) can cover 6m in radius and 90º horizontally and 20º vertically.

2m

15º

PIR alarm with remote control

Version  07/14

Item no. 751170

Intended use

The PIR alarm is intended to alert the resident if an intruder is detected within the area covered 

by the PIR sensor. The sensor detects motion by sensing the heat emitted from an object 

moving across its detecting area. The alarm has been fine tuned so that false alarms are 

minimal. It is armed/ disarmed by remote control and is equipped with a powerful 110dB audio 

alarm.
The main unit must be connected with a suitable 9 V/DC power adapter (not included) during 

operation. 4 pieces 1.5 V/DC batteries type AA (not included) serve as back-up batteries, in 

case of a short term mains power failure.
The main unit should be operated in dry indoor or protected outdoor area. It is ideal for 

apartment, garage, shed, caravan or boat.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you 

use the product for purposes other than those described above, the product may be damaged. 

In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc. 

Read the instructions carefully and keep them. Make this product available to third parties only 

together with its operating instructions.
This product complies with the statutory national and European requirements. All company 

names and product names are trademarks of their respective owners. All rights reserved.

Delivery content

•  PIR alarm
•  Mounting bracket
•  Remote control
•  3 x 1.5 V/DC button cells
•  2 x screws, 2 x wall plugs
•  Operating instructions

Safety instructions

Read the operating instructions carefully and especially observe the safety 

information. If you do not follow the safety instructions and information 

on proper handling in this manual, we assume no liability for any resulting 

personal injury or damage to property. Such cases will invalidate the warranty/

guarantee.

a) Persons / Product

•  The device is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. These may become 

dangerous playing material for children.

•  Protect the product from extreme temperatures, direct sunlight, strong jolts, high 

humidity, moisture, flammable gases, vapours and solvents.

•  Do not place the product under any mechanical stress.
•  If it is no longer possible to operate the product safely, take it out of operation and 

protect it from any accidental use. Safe operation can no longer be guaranteed if 

the product:

 - is visibly damaged, 
 - is no longer working properly, 
 - has been stored for extended periods in poor ambient conditions or 
 - has been subjected to any serious transport-related stresses.

•  Please handle the product carefully. Jolts, impacts or a fall even from a low height 

can damage the product.

•  Also observe the safety and operating instructions of any other devices which are 

connected to the product.

•  The main unit should be placed away from heaters, ovens and other sources of 

heat.

•  The main unit should not be directed toward heaters, fans, air exhaust or clothes 

dryer, air conditioner, open window, direct sunlight, swimming pool, pond, luminous 

sign. Any kind of temperature change can cause spurious detection.

Summary of Contents for 751170

Page 1: ...mungsgem e Verwendung Der PIR Alarm ist daf r vorgesehen den Benutzer zu warnen falls eine unbefugte Person innerhalb des Bereiches festgestellt wird der durch den PIR Sensor abgedeckt wird Der Sensor...

Page 2: ...ngerem Stromausfall und abfallender Spannung der St tzbatterien wird der Alarmton bei einer Spannung der St tzbatterien zwischen 4 0 V und 6 0 V normale Spannung wie folgt ausgel st Im Aktivierungsmo...

Page 3: ...l Version 07 14 Item no 751170 Intended use The PIR alarm is intended to alert the resident if an intruder is detected within the area covered by the PIR sensor The sensor detects motion by sensing th...

Page 4: ...Maintenance and cleaning Do not use any aggressive cleaning agents rubbing alcohol or other chemical solutions as they can cause damage to the housing and malfunctioning Never submerge the product in...

Page 5: ...R Le capteur d tecte les mouvements en captant la chaleur corporelle des objets qui se d placent travers sa zone de d tection L alarme a t r gl e avec pr cision afin de minimiser les fausses alertes E...

Page 6: ...nettoyage N utilisez en aucun cas des produits de nettoyage agressifs base d alcool ou toute autre solution chimique car ceux ci pourraient endommager le bo tier et nuire au bon fonctionnement de l a...

Page 7: ...k Het op scherp zetten neutraalstellen van het alarm gaat met de afstandsbediening en de installatie is voorzien van een krachtig 110 dB audio alarm Tijdens de werking dient de hoofdeenheid met een co...

Page 8: ...ugkeren naar de stand by modus In het andere geval wordt een hoorbaar waarschuwingssignaal opgewekt De rode status LED 8 blijft ingeschakeld Het alarm zal gedurende 40 50 seconden aanhouden totdat het...

Reviews: