After installing of the door/window detector as described in section
7. b) on pages 11 to 13, the casing of the device is still open and
the batteries are not yet inserted.
• If you want to connect additional NC contacts to the ‘KL2’ connector, first
remove the jumper from the KL2 connector. When connecting several external
NC contacts, they must be connected in series. Do not connect terminating
resistors.
Please refer to figure 2 on page 9 for
connecting NC contacts.
• Insert 3 AAA batteries into the 3 battery
holders making sure polarity is correct. See
figure 6.
• The door/window detector contacts the
alarm base station by sending a radio signal.
The LED of the door/window detector
briefly lights up and the alarm base station
emits a short signal tone to confirm signal
reception.
• If the internal magnet contact is to be used
(with the supplied magnets), close the
window that the magnet is attached to.
This activates the internal magnet.
You may need to open and close the
windows again to ensure that a radio
signal is sent to the alarm base station.