background image

Air Humidity Control

Version 12/10

Item-No. 56 16 00

°

Use in accordance with manufacturer’s instructions

The air humidity control measures the humidity via an integrated sensor. A load connected to the
front socket of the air humidity controller can be switched on or off when the air humidity exceeds
a defined value or falls below it.

E.g. an air humidifier (if the ambient air is too dry) or an air dehumidifier (if the air humidity is too
high) that does not have its own air humidity control can be connected to this controller. 

Any use other than that described above is not permitted and may damage the product; fur-
thermore, it may involve other risks, such as short-circuit, fire, electric shock, etc. Do not change
or modify any part of the product.

Always observe the safety instructions and technical specifications! Please read the operating
instructions carefully and store them.

This product complies with the applicable national and European requirements. All names of
companies and products are the trademarks of the respective owner. All rights reserved.

Package Contents

• Humidity control

• Operating Instructions

Explanation of the Symbols

This symbol indicates a health hazard, e.g. electric shock.

The exclamation mark indicates particular risks in handling, function and use.

The “Hand” symbol indicates special tips and operating information.

Safety Instructions

The warranty will be void in the event of damage caused by failure to observe
these safety instructions. We do not assume any liability for any resulting
damage! 

We do not accept liability for damage to property or personal injury caused by
improper handling or non-compliance with the safety instructions! The
warranty will be void in such cases! 

• The unauthorised conversion and/or modification of the product is not allowed for

safety and approval reasons (CE). Never dismantle the product!

• The product is designed in accordance with protection class I. Only a standard

mains socket (with protective earth) for the public supplygrid may be used as a
power source.

• The product is not a toy and must be kept out of the reach of children! There is the

risk of a fatal electric shock!

• The product is used to control a connected load depending on the air humidity.

However, the product must not get wet or damp; that poses a danger to life through
electric shock! It must be used in dry interior spaces only!

• Never touch the product, or the mains plug, with wet or damp hands when trying

to connect a plug to the front socket. There is a risk of a lethal electric shock! The
same applies to the humidity control itself.

• Never pull out a mains plug by pulling on its cable when disconnecting it from the

front socket of the humidity controller. Always pull the plug out of the front socket
by gripping the area provided for this purpose on its sides.

• Do not use the humidity controller in rooms or under adverse ambient conditions

where combustible gases, vapours or dust are or may be present! There is a risk
of explosion!

• Do not overload the product (take note of the input power in the technical data at

the end of the operating manual!).

• The product must not be exposed to extreme temperatures, strong vibrations or

heavy mechanical stress.

• Only use the product is when it has been securely mounted.

O P E R A T I N G   I N S T R U C T I O N S

www.conrad.com

• If you have reason to assume that safe operation is no longer possible, disconnect

the product immediately and secure it against accidental operation. Let an expert
check the product.

It can be assumed that safe operation is no longer possible if:

- the product shows visible signs of damage,

- the product does not work at all or well (flickering light, leaking smoke or a smell

of burning, audible cracking noises, discolouration to the product or the adjacent
surfaces.)

- the device was stored under unfavourable conditions for a long period of time or

- the device was exposed to extraordinary stress caused by transport.

• If the product casing is damaged, do not use the product anymore! When it is

connected to the mains, do not touch the humidity controller or the connected
device! First switch off at the mains socket to which the humidity controller is
connected (switch off the circuit breaker). 

Disconnect any device that is connected to the humidity control; then unplug the
humidity control from the mains socket. Take the product to a specialist workshop
or dispose of it in an environmentally friendly way.

• Do not leave packing materials unattended. They may become dangerous

playthings for children.

• In commercial institutions, the accident prevention regulations of the employer’s

liability insurance association for electrical systems and operating facilities are to
be observed!

• If you have any questions that are not answered in this manual, please contact our

technical service or another specialist.

Initial start-up, recharging the integrated accumulator 

The air humidity controller features a built-in NiMH rechargeable battery/accumulator. The
accumulator serves to prevent data loss in the event of a power failure. 

Furthermore, the humidity control (with fully charged accumulator) can be pro-
grammed even if it is not connected to a mains socket. 

The accumulator is fully charged if the humidity control has been connected to the
mains voltage for approx. 12 hours. 

At delivery, the NiMH battery is usually empty. Nothing is shown in the display.  
In order to perform the programming, connect the humidity control to a mains socket. Shortly
after, the display will be activated and you can start up the humidity controller.  

Choose operating mode

If the NiMH accumulator integrated in the humidity control is charged, the pro-
gramming can be performed even though the humidy control is not connected to the
mains socket.  If the display does not work, the NiMH accumulator is empty.  In this
case, plug the humidity controller into a mains socket to perform the programming. 

If “SET” is shown at the display’s top right-hand side, press the

” button briefly in order for the humidity control to change

to the setting mode for the corresponding operating mode; see
illustration to the right. 

Now the display shows the currently measured air humidity at
the bottom left and the currently selected operating mode at
the top: 

Operating mode 1:

Display “

”  = Air humidification: a load is switched on if the

humidity in the room falls below a preset value.

This operating mode must be selected if you have
connected an air humidifier. 

Operating mode 2:

Display “

”  = Air dehumidification: a load is switched on if the

humidity in the room exceeds a preset value.

This operating mode must be selected if you have
connected an air dehumidifier or a ventilation
system. 

To change the operating mode, proceed as follows:

• Press and hold the “

” key (do not release).  

• In addition, press and hold the “

” key.

• After approx. 2 to 3 seconds the operating mode changes. Now release both buttons. 

Summary of Contents for 56 16 00

Page 1: ...n B E D I E N U N G S A N L E I T U N G www conrad com Wenn anzunehmen ist dass ein gefahrloser Betrieb nicht mehr m glich ist so ist das Produkt au er Betrieb zu setzen und gegen unbeabsichtigten Bet...

Page 2: ...Luftbefeuchter wieder eingeschaltet Die LED links neben dem Display zeigt Ihnen an ob die Frontsteckdose und damit der Luftbefeuchter ein oder ausgeschaltet ist LED leuchtet rot Aus LED leuchtet gr n...

Page 3: ...eason to assume that safe operation is no longer possible disconnect the product immediately and secure it against accidental operation Let an expert check the product It can be assumed that safe oper...

Page 4: ...the air humidifier will be turned on again The LED to the left of the display indicates whether the front socket and thus the air humidifier is switched on or off LED illuminates red Off LED illuminat...

Page 5: ...n L appareil ne doit pas tre expos des temp ratures extr mes aux rayons du soleil de fortes vibrations ou l humidit Le produit ne doit fonctionner qu en position stationnaire M O D E D E M P L O I www...

Page 6: ...l cran vous indique si la prise frontale et donc l humidificateur sont activ s ou d sactiv s La LED s allume en rouge Arr t La LED s allume en vert Marche Mode 2 d shumidification Cette fonction peut...

Page 7: ...d com Stel als aannemelijk is dat gevaarloos gebruik niet langer mogelijk is het pro duct buiten bedrijf en borg het tegen onbedoeld gebruik Laat een vakman ver volgens het product controleren U mag a...

Page 8: ...eld De LED links naast de display geeft aan of de frontcontactdoos en dus de lucht bevochtiger in resp uitgeschakeld is LED licht rood op Uit LED gaat groen branden Aan Bedrijfsmodus 2 luchtontvochtig...