11.17 Menu „ALARM SETUP“
The ALARM RECORD DURATION states how long
(in seconds) a recording is supposed to run as of the
time of motion detection or as of the time of triggering
a sensor.
ALARM DURATION:
Using the setting ALARM DURATION, you can
define how long the relay output ALARM is to be acti-
vated at the „connection terminal“ (30): upon motion
detection or upon triggering a sensor.
BUZZER DURATION:
With this setting you can define how long the internal
acoustic alarm is to be activated as of the time of
motion detection or upon triggering a sensor.
The following settings are possible:
OFF (= acoustic alarm is deactivated)
5, 10, 15, 20, 25, 30 (= time in seconds of the
acoustic alarm)
CONT (= continuous acoustic alarm which can only
be deactivated by pressing a button)
11.17.1 Submenu SENSOR SETUP“.
IIn this menu you have to set which type of make con-
tact is connected to the corresponding sensor con-
nections on the connection terminal (30).
Possible settings:
• NOT INSTALLED (= no sensor connected)
• TYPE: NORMAL-OPEN (= a sensor with NO con-
tact is connected)
• TYPE: NORMAL-CLOSE (= a sensor with NC
contact is connected)
☞
If you are not sure about the type of make close your sensor operates, contact an
expert.