Sample:
In this case an IR CTRL is prompted by a control computer to address a component which is assig-
ned the IR address 30 and to transmit the Command 22 to this component.
The data frame for the IR-CTRL:
The RC5 IR data frame transmitted:
S = Start bit
T = Toggle (toggled as a rule to the remote control with every new keystroke)
A = Address
C = Command
The REC80 IR data frame transmitted:
S = Start bit
A = Address
C = Command
18
IR MODULE IR-CTRL
Byte 1
Byte 2
Byte 3
Command
Adress
Subcommand
22
30
0
S
S
T
A4
A3
A2
A1
A0
C5
C4
C3
C2
C1
C0
1
1
x
1
1
1
1
0
0
1
0
1
1
0
30
22
S
A4
A3
A2
A1
A0
C6
C5
C4
C3
C2
C1
C0
1
1
1
1
1
0
0
0
1
0
1
1
0
30
22
Summary of Contents for IR-CTRL