RS422/485 (Port-5) Settings
Command Operation
Notes
P5?
Query the Port-5 mode of operation
RSZ?
Query the Termination state of Port-5
P5=v
Set the Port-5 mode of operation
v = ‘F’ for Full Duplex
‘H’ for ½ Duplex
‘J’ for J1708 mode
RSZ=v
Set the Termination state of Port-5
v = ‘T’ to enable the Termination
‘O’ to disable the Termination