Copyright
©
2019
congatec
AG
JCWLm10
35/55
Note
1. EDID signals and VDDEN output are 3.3 V.
2. The maximum output current for LCD and backlight power rails is 1.5 A.
3. Use ODD pins for single channel LVDS panel.
4. eDP support via assembly option
Connector Type
X15: 40-pin, 1 mm pitch header (JST BM40B-SRDS-G-TF)
Possible Mating Connector: JST SHDR-40V-S-B
5.3.3.1
Panel Voltage Selection Jumper
The conga-JC370 supports 3.3 V, 5 V and 12 V LCD panels. Use jumper JP1 to set the panel voltage.
Table 20 JP1 Pinout Description
Jumper
Panel Voltage
2-4
5 V
3-4
12 V
4-6
3.3 V (default)
Connector Type
JP1: 2.54 mm, 2 x 3-pin header (without pins 1 and 5)
JP1
Pin 2
Pin 6
No Pin
No Pin
Pin 3