background image

Copyright 

© 

2021 

congatec 

GmbH 

 

      GEVAm03 

       

38/65

4.5.2 

Dual Stacked USB 2.0 Type-A Ports

The conga-HPC/EVAL-Client provides two USB 2.0 ports via a dual-stacked USB Type-A connector (X25). Each port provides up to 1.7 A.

 

Connector Type

X25: USB Type-A plug

4.6 

SATA

The conga-HPC/EVAL-Client provides two standard SATA connectors (X32, X33):

 

SATA0 port on connector X32

 

SATA1 port on connector X33

 

Connector Type

X32, X33: Standard SATA plug

4.6.1 

Disk Drive Power Connector

The conga-HPC/EVAL-Client provides connector X35, a 4-pin connector for powering disk drives. 

 

Caution

Do not connect more than one peripheral device to connector X35. The peripherals may damage if you do so. 

Table 29   X35 - Disk Drive Power Pinout

Pin

Description

1

12 V (1.5 A fuse; resettable; shared with X34)

2

GND

3

GND

4

5 V (2 A fuse; resettable; shared with X34)

 

Connector Type

X35: Standard 4-pin disk drive power plug

X25

7   6   5    4   3   2  1

X32, X33

X35

Summary of Contents for conga-HPC/EVAL-Client

Page 1: ...Copyright 2021 congatec GmbH GEVAm03 1 65 conga HPC EVAL Client Detailed description of the congatec COM HPC Client Module Size A B C evaluation carrier board User s Guide Revision 0 3 Preliminary...

Page 2: ...uthor Changes 0 1 2021 03 15 BEU Preliminary release 0 2 2021 04 14 BEU Updated operating and storage temperature in section 3 1 Feature List and 3 3 Environmental Specifications 0 3 2021 07 26 BEU Ad...

Page 3: ...tware is provided by its programmers without ANY WARRANTY whether implied or expressed of any fitness for a particular purpose and the programmers DECLINE ALL LIABILITY for damages direct or indirect...

Page 4: ...tatic electromagnetic magnetic or radioactive fields unless the device is contained within its original packaging Be aware that failure to comply with these guidelines will void the congatec GmbH Limi...

Page 5: ...hardware or loss of data Note Notes call attention to important information that should be observed Connector Type Describes the connector that must be used with the congatec evaluation carrier board...

Page 6: ...air warranty period in effect as of the date the repaired exchanged or replaced product is shipped by congatec or the remainder of the original warranty whichever is longer This Limited Warranty exten...

Page 7: ...A Serial AT Attachment HDA High Definition Audio I C Bus Inter Integrated Circuit Bus SM Bus System Management Bus GbE Gigabit Ethernet LVDS Low Voltage Differential Signaling HBR3 High Bit Rate 3 DDC...

Page 8: ...4 2 4 Flat Panel and Backlight Voltage Selection 36 4 4 2 5 Flat Panel Configuration Data 37 4 5 Universal Serial Bus USB 37 4 5 1 USB4 Type C Ports 37 4 5 2 Dual Stacked USB 2 0 Type A Ports 38 4 6...

Page 9: ...ongatec GmbH GEVAm03 9 65 5 Additional Features 62 5 1 Buttons 62 5 1 1 Power 62 5 1 2 Reset 62 5 1 3 LID 62 5 1 4 Sleep 63 5 2 Ground Test Points 63 5 3 Debug Display 63 5 4 Debug LEDs 64 6 Mechanica...

Page 10: ...tion 39 Table 32 X36 NBASET0_SDP Header Pinout 40 Table 33 X38 NBASET1_SDP Header Pinout 40 Table 34 X54 Ethernet Mezzanine Card Connector Pinout 40 Table 35 X49 Audio Jack Pinout 42 Table 36 X50 I S...

Page 11: ...terface Summary Features Classification Client Module Min Max Server Module Min Max Comment Ethernet NBASE T 1 2 1 1 KR KX 0 2 2 8 SATA 0 2 0 2 PCIe Lane 0 47 4 48 8 48 Lane 48 63 N A 0 16 BMC 0 1 1 1...

Page 12: ...ining the scalability of COM HPC Client Modules the conga HPC EVAL Client carrier board provides manufacturers and developers with a platform to jump start the development of systems and applications...

Page 13: ...R661 R662 R663 R514 C43 C39 C37 C38 C798 C799 C800 C801 C802 C803 C804 C805 C52 C50 C47 C49 C694 D67 D66 D69 D68 C51 C48 C45 C46 C698 R507 R508 FB68 FB66 FB64 FB65 FB67 FB60 FB61 FB63 FB62 F11 FB58 F...

Page 14: ...a SIO 1x GPSPI header 1x I2C header 1x SMB header 1x GPIO header 1x Feature header 1x System Fan 1x CPU Fan External Connectors 1x Dual USB 2 3x DP 2x 10GbE RJ45 2x USB4 1x Audio Jack 4 pin with SNDW...

Page 15: ...3 3 Environmental Specifications Temperature Operation 0 C to 60 C Storage 20 C to 70 C Humidity Operation 10 to 90 Storage 5 to 95 Note The above operating temperatures must be strictly adhered to at...

Page 16: ...7 USB6 B17 USB4 C17 USB2 D17 USB0 A18 USB6 B18 GND C18 USB2 D18 GND A19 GND B19 I2S_LRCLK SNDW_CLK3 C19 GND D19 DDI0_SDA_AUX A20 DDI1_SDA_AUX B20 I2S_DOUT SNDW_DAT3 C20 SNDW_DMIC_CLK1 D20 DDI0_SCL_AUX...

Page 17: ...PI_ALERT0 C52 BOOT_SPI_IO2 D52 SATA0_TX A53 eSPI_IO3 B53 eSPI_ALERT1 C53 BOOT_SPI_IO3 D53 SATA0_TX A54 eSPI_CLK B54 eSPI_CS0 C54 BOOT_SPI_CLK D54 GND A55 GND B55 eSPI_CS1 C55 GND D55 SATA1_RX A56 PCIe...

Page 18: ...CC_RTC B86 RSMRST_OUT C86 SMB_CLK D86 NBASET0_MDI0 A87 SUS_CLK B87 UART1_TX C87 SMB_DAT D87 GND A88 GPIO_00 B88 UART1_RX C88 SMB_ALERT D88 NBASET0_MDI1 A89 GPIO_01 B89 UART1_RTS C89 UART0_TX D89 NBASE...

Page 19: ...VD G16 USB3_LSTX H16 GND E17 GND F17 RSVD G17 USB2_LSRX H17 USB3_AUX E18 DDI2_DDC_AUX_SEL F18 RSVD G18 USB2_LSTX H18 USB3_AUX E19 DDI2_HPD F19 GND G19 PEG_LANE_REV H19 GND E20 GND F20 PCIe32_RX G20 GN...

Page 20: ...E56 GND F56 PCIe20_RX G56 GND H56 PCIe28_TX E57 PCIe20_TX F57 PCIe20_RX G57 PCIe28_RX H57 PCIe28_TX E58 PCIe20_TX F58 GND G58 PCIe28_RX H58 GND E59 GND F59 PCIe21_RX G59 GND H59 PCIe29_TX E60 PCIe21_T...

Page 21: ...9 GND F89 ETH1_TX G89 CSI0_MCLK H89 CSI1_RST E90 ETH1_RX F90 ETH1_TX G90 CSI0_RST H90 CSI1_ENA E91 ETH1_RX F91 GND G91 CSI0_ENA H91 GND E92 GND F92 PCIe_REFCLK2 G92 GND H92 PCIe_REFCLKIN0 E93 PCIe_REF...

Page 22: ...power is supplied via the DC banana jacks the onboard DC DC regulators generate the 3 3 V 5 V and 12 V The onboard buck boost converter generates the 12 V from 8 21 Vmax 4 1 1 ATX Power Connectors The...

Page 23: ...GND Power ground 15 GND Power ground 4 5V Power supply 5 VDC 16 PS_ON Power Supply On active low Short this pin to GND to switch power supply ON disconnect from GND to switch OFF 5 GND Power ground 1...

Page 24: ...f banana jacks to power the system Although the carrier board is designed for the input voltage range of 8 21 Vmax the input voltage range is defined by the module For more information see section 4 1...

Page 25: ...wer is applied to the conga HPC EVAL Client D78 On The yellow LED indicates that the onboard 3 3 V standby power is present D79 On The green LED indicates that 12 V main power is present D80 On The gr...

Page 26: ...etection The signals TYPE0 TYPE1 and TYPE2 indicate the pinout type of the module connected to the carrier board These pins are either open NC or strapped to ground GND by the module as shown in the t...

Page 27: ...s battery holder M18 for a CR2032 battery The battery supplies power to the RTC and CMOS memory Warning Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent...

Page 28: ...ion If other PCIe Bifurcation options are required contact congatec technical support 4 3 1 PCIe x16 Slots The conga HPC EVAL Client provides two standard PCIe x16 slots PCIe lanes 16 31 on connector...

Page 29: ...x4 slots X7 X8 X10 M 2 Key B X12 M 2 Key E X15 Table 17 JP1 PCIe Clock Request Signal Settings Pin Description 1 2 Enable permanently 2 3 Enable default Connector Type JP1 2 54 mm 2 pin jumper 4 3 3 P...

Page 30: ...et The UIM interface of the M 2 Key B socket is connected to micro SIM card slot X13 Connector Type X12 M 2 Key B card size 3042 2242 2260 2280 X13 micro SIM card The clock request signal PCIe_CLKREQ0...

Page 31: ...ble 20 SW2 M 2 Key B Settings Switch Configuration Description SW2 2 OFF Deactivate M 2 reset control default ON Activate M 2 reset control SW2 3 OFF Deactivate M 2 WDIS2 control wireless 2 default ON...

Page 32: ...the M 2 Key E settings as described in the table below Table 22 SW3 M 2 Key E Control Switch Configuration Description SW3 1 OFF Deactivate M 2 WDIS1 control wireless 1 default ON Activate M 2 WDIS1...

Page 33: ...Port re driver to support HBR3 data rate up to 12 Gbps Connector Type X26 X27 X28 Standard DP plug 4 4 2 eDP LVDS The conga HPC EVAL Client connects the module s eDP LVDS interface to eDP panel on con...

Page 34: ...9 LVDS0_D1 10 LVDS0_D1 11 LCD0_BKLTEN 12 LVDS0_D2 13 LVDS0_D2 14 NC 15 LVDS0_CLK 16 LVDS0_CLK 17 NC 18 LVDS0_D3 19 LVDS0_D3 20 GND 21 LVDS1_D0 22 LVDS1_D0 23 GND 24 LVDS1_D1 25 LVDS1_D1 26 GND 27 LVD...

Page 35: ..._TX2 27 eDP_HPD 8 GND 28 GND 9 eDP_TX1 29 GND 10 eDP_TX1 30 GND 11 GND 31 GND 12 eDP_TX0 32 eDP_LVDS_BKLT_EN 13 eDP_TX0 33 eDP_LVDS_BKLT_CTRL 14 GND 34 N C 15 eDP _AUX 35 N C 16 eDP_AUX 36 N C 17 GND...

Page 36: ...DD_EN 6 EDP_BKLT_EN 7 N C 8 EDP_BKLT_CTRL_R 9 GND 10 GND Connector Type X31 2 54 mm 2x5 pin female connector 4 4 2 4 Flat Panel and Backlight Voltage Selection The conga HPC EVAL Client supports diffe...

Page 37: ...s four USB4 Type C port 0 on connector X19 port 1 on connector X20 port 2 on connector X22 port 3 on connector X23 two USB 2 0 Type A dual stacked ports 4 and 5 on connector X25 USB 2 0 M 2 Key B port...

Page 38: ...X32 SATA1 port on connector X33 Connector Type X32 X33 Standard SATA plug 4 6 1 Disk Drive Power Connector The conga HPC EVAL Client provides connector X35 a 4 pin connector for powering disk drives...

Page 39: ...rovides RJ45 ethernet ports X37 and X39 The NBASE T Ethernet Controller 0 1 Software Definable Pins SDP NBASET 0 1 _SDP are provided on pin headers X36 and X38 ETH0 port on connector X37 NBASET0_SDP o...

Page 40: ...an Ethernet Mezzanine card Table 34 X54 Ethernet Mezzanine Card Connector Pinout Pin Signal Pin Signal Pin Signal Pin Signal A1 GND B1 ETH0_RX0P C1 GND D1 GND A2 GND B2 ETH0_RX0N C2 GND D2 ETH0_SDP A3...

Page 41: ...B23 GND C23 NC D23 GND A24 NC B24 GND C24 NC D24 NC A25 GND B25 NC C25 GND D25 NC A26 GND B26 NC C26 GND D26 NC A27 NC B27 GND C27 NC D27 GND A28 NC B28 GND C28 NC D28 NC A29 GND B29 NC C29 GND D29 NC...

Page 42: ...altek ALC711 Table 35 X49 Audio Jack Pinout Pin Jack Signal Description 1 Tip LINE_L Line OUT left channel 2 Ring 1 LINE_R Line OUT right channel 3 Ring 2 A_GND Analog ground 4 Sleeve MIC Microphone C...

Page 43: ...n defines two general purpose I C buses I2C 0 1 I2C0 Bus The conga HPC EVAL Client provides the I2C0 signals on connector X52 and X59 For more information see section 4 23 I2C I O Expander Pin Header...

Page 44: ...r Type U55 2 wire 3 3 V Serial EEPROMS in 8 pin DIL package 4 11 SPI Flash Socket The conga HPC EVAL Client provides a 16 pin SOIC16 socket X51 for an SPI flash Connector Type X51 SPI flash in 16 pin...

Page 45: ...arrier BIOS on SPI0 on Carrier or on SPI1 on Module 101 Carrier J1 B54 Carrier J1 B55 Module Carrier J1 B48 Module MAFS on Module Casino Gaming Removable BIOS option on Carrier Alternate version CSME...

Page 46: ...BOOT_SPI 7 SPI_CLK_ISP 8 SPI_IO2_ISP 9 SPI_IO3_ISP 10 SPI_IO1_ISP 11 NC 12 SPI_IO0_ISP 13 NC 14 NC 15 NC 16 NC 17 NC 18 NC 19 PLTRST 20 NC Use jumper JP8 to select the DEBUG_RST trigger signal of the...

Page 47: ...3 3A 14 GP_SPI_ALERT 15 GP_SPI_CS2 16 GP_SPI_CS3 Connector Type CN2 2 54 mm 2x8 pin female connector 4 14 eSPI On the conga HPC EVAL Client the module s eSPI interface is routed to a Super I O control...

Page 48: ...or Super I O OFF Selects eSPI_CS1 for Super I O default Use DIP SW5 to configure the Super I O Table 44 SW5 Super I O Settings Switch Configuration Description SW5 1 OFF Configuration IO address 2Eh d...

Page 49: ...PI_ALERT0 Connector Type X44 2 54 mm 2x7 pin female connector 4 14 2 Serial Ports The conga HPC EVAL Client supports up to four serial ports Super I O COM port 0 RS 232 422 485 on connector X46 Super...

Page 50: ...RS 485 RS 422 full duplex Table 47 SW8 COM Port 0 Transceiver Settings Switch Configuration Description SW8 1 OFF 1 Mbps SLEW ON 250 kbps SLEW LIMITING for EMI SW8 2 OFF RS 485 422 Termination disabl...

Page 51: ...X45 2 54 mm 2 x 5 pin female connector Note This port supports RS 232 I O voltage levels only 4 14 2 3 Module Serial Port 0 The conga HPC EVAL Client provides the module s serial port 0 UART0 on head...

Page 52: ...ovides the module s serial port 1 UART1 on header X43 UART1 is also connected to the M 2 key E slot X15 and feature connector X55 For more information see section 4 3 5 M 2 Key E and section 4 17 Feat...

Page 53: ...supply voltage level Table 55 JP6 Fan Voltage Settings Pin Description 1 2 12 V supply voltage for auxiliary fan default 2 3 5 V supply voltage for auxiliary fan Use jumper JP7 to select the fan s con...

Page 54: ...JP10 CPU Fan Voltage Control Pin Configuration 1 2 12 V supply voltage default 2 3 5 V supply voltage Connector Type X62 2 54 mm 4 pin fan plug JP10 2 54 mm grid jumper 4 16 Debug Header The conga HP...

Page 55: ...pose wake up signal May be used to implement wake up on PS2 keyboard or mouse activity 13 WD_OUT Output indicating that a watchdog time out event has occurred 14 PEG_LANE_ REV PCI Express Graphics lan...

Page 56: ...03 10 GND 11 GPIO_04 12 GND 13 GPIO_05 14 GND 15 GPIO_06 16 GND 17 GPIO_07 18 GND 19 GPIO_08 20 GND 21 GPIO_09 22 GND 23 GPIO_10 24 GND 25 GPIO_11 26 GND Connector Type X58 2 54 mm 2x13 pin female con...

Page 57: ...dby 0 75 A fuse 2 I2C0_DAT 3 I2C0_CLK 4 I2C0_ALERT 5 GND Connector Type X59 2 54 mm 5 pin female connector 4 20 I2C1 Pin Header The conga HPC EVAL Client provides I2C1 pins on header X60 I2C1 is defin...

Page 58: ...5 A fuse 2 SMB_DAT 3 SMB_CLK 4 SMB_ALERT 5 GND Connector Type X61 2 54 mm 5 pin female connector 4 22 Front Panel Pin Header The conga HPC EVAL Client provides front panel pins on header X56 Table 65...

Page 59: ...6 X52 I2C Header Pinout Pin Signal Pin Signal 1 I2C_IOE_B0 2 GND 3 I2C_IOE_B1 4 GND 5 I2C_IOE_B2 6 GND 7 I2C_IOE_B3 8 GND 9 I2C_IOE_B4 10 GND 11 I2C_IOE_B5 12 GND 13 I2C_IOE_B6 14 GND 15 I2C_IOE_B7 16...

Page 60: ...3 CSI0_RX0P 4 CSI0_RX0N 5 GND 6 CSI0_RX1P 7 CSI0_RX1N 8 GND 9 CSI0_RX2P 10 CSI0_RX2N 11 CSI0_RST 12 CSI0_RX3P 13 CSI0_RX3N 14 GND 15 CSI0_CLKP 16 CSI0_CLKN 17 GND 18 CSI0_I2C_CLK 19 CSI0_I2C_DAT 20 C...

Page 61: ...3 CSI1_RX0P 4 CSI1_RX0N 5 GND 6 CSI1_RX1P 7 CSI1_RX1N 8 GND 9 CSI1_RX2P 10 CSI1_RX2N 11 CSI1_RST 12 CSI1_RX3P 13 CSI1_RX3N 14 GND 15 CSI1_CLKP 16 CSI1_CLKN 17 GND 18 CSI1_I2C_CLK 19 CSI1_I2C_DAT 20 C...

Page 62: ...te to another for example from S5 to S0 However the system s behavior depends on the ACPI settings of the Operating System 5 1 2 Reset When you press the reset button SW12 it triggers the module s RST...

Page 63: ...test points M1 M4 These test points are connected to ground and they make it easier to connect oscilloscope probes or multimeter lines or both to ground during measurements 5 3 Debug Display The conga...

Page 64: ...C EVAL Client provides eight LEDs D47 D54 for post code or debug information in binary format A list of the BIOS POST codes and associated POST test and initialization routines for congatec COM HPC mo...

Page 65: ...Copyright 2021 congatec GmbH GEVAm03 65 65 6 Mechanical Dimensions...