Jumper JP12 can be used to manually set the TYPE0 signal to NC (Client Module 8-20V).
Table 15 JP12 - TYPE0 Signal Settings
Pin
Description
1-2
Check module TYPE0 signal (default)
2-3
NC (Client Module 8-20V)
Connector Type
JP12: 2.54 mm, 2-pin jumper
4.2
CMOS Battery Holder
The conga-HPC/EVAL-Client provides battery holder M18 for a CR2032 battery. The battery supplies power to the RTC and CMOS memory.
Warning
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
Jumper JP9 can be used to disconnect the battery.
Table 16 JP9 - Battery Settings
Pin
Description
1 - 2
Connect battery (default)
2 - 3
Disconnect the battery
Connector Type
JP9: 2.54 mm, 2-pin jumper
M18: CR2032 battery