Confycare EL08 Manual Download Page 4

    EN 

 

  

 

 

This table generates, uses, and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful 
interference to other devices in the vicinity. However, 
there is no guarantee that interference will not occur in 
a particular installation. Harmful interference to other 
devices can be determined by turning this table on 
and off. Try to correct the interference using one or 
more of the following: reorient or relocate the receiving 
device, increase separation between the equipment, 
connect the table to an outlet on a different circuit from 
that which the other device(s) are connected, and 
consult Coinfycare or your local dealer for help. 

Unplug the table from the power supply before starting 
cleaning or any type of maintenance operations. 

The table should be kept out of the reach of children 
when there is no adult supervision. 

The table is designed for discontinuous interval 
operation, so the continuous running time of the motor 
should never exceed 2 minutes. Should this happen, 
damage may occur due to overheating of the 
electronics. 

Always use original accessories and spare parts 
provided by your local

 

dealer. 

Always cover the table with a towel, disposable paper 
or a cover and change it for each user, thus ensuring 
correct hygiene and extending the useful life of the 
upholstery. 

Only connect the table to a properly installed and 
grounded outlet. The local mains voltage must 
correspond to the technical data of the device. 

The power outlet should be accessible in case 
the table needs to be quickly unplugged at any 
given time. Always pull the plug and not the mains 
cable.  

 

TECHNICAL SPECIFICATIONS 

Product dimensions 

EL08 - Base Chiropractic Table 

Length: 1800-1930mm 
Width: 550mm 
Lifting stroke distance: 220mm 
Lifting range of bed surface: 450-770mm 

EL08B - Chiropractic Breakaway Table 

Length: 1800-1930mm 
Width: 550mm 
Lifting stroke distance: 220mm 
Lifting range of bed surface: 450-770mm 

EL08F - Premium Chiropractic Table 

Length: 1800-1950mm 
Width: 660mm 
Lifting range of bed surface: 600-800mm 

Included angle between head plate and horizontal 
plane: -

20°≤A≤25° 

Included angle between leg plate and chest plate: 
0°≤B≤25° 

EL08FS - Stationary Chiropractic Table 

Length: 1730-1890mm 
Width: 530mm 
Fixed table height: 550mm 
Included angle between head plate and horizontal 
plane: -

20°≤A≤15° 

Included angle between leg plate and chest plate: 
0°≤B≤30° 

 

If the electrical supply cable is defective, 
disconnect the table immediately and inform your 
dealer or a specialized technician. 

Position the power cord properly so that it cannot be 
tripped over. 

Unplug the power cord from the mains if the table is 
not going to be used for a long period of time. 

If you detect any abnormality in the operation of the 
table, consult your dealer or a specialized technician. 

Never manipulate any electrical part or open or 
repair any part of the table. 

Only your dealer or a specialized technician should 
repair the table. 

Never touch the table or the power cord with wet 
hands. 

Never place your hands or any other part of your 
body in any hole or void on the table while it is in 
operation. 

Make sure there are no objects in the space under 
the table that could cause collisions or entrapment 
during operation. 

Make sure that your feet are not resting on the 
peripheral foot bar or foot control during treatment 
and especially when sitting near the table. This 
could create a dangerous situation where your leg 
is caught between the section and the peripheral 
foot bar or floor surface. 

Take into account the weight distribution on the 
table when working. The weight must be distributed 
along the table without concentrating on its ends to 
maintain the correct stability. 

You should not sit on the head and foot sections. If 
you do there is a danger of tipping and table damage. 

 
 

PLACEMENT IN THE 
WORKPLACE 

The table has two wheels to facilitate movement 
to the place where it will be used. 
Once correctly positioned, the table has two 
adjustable feet that prevents it from moving during 
use. 

Summary of Contents for EL08

Page 1: ...EL08 EL08B EL08F EL08FS Electrical Chiropractic Table...

Page 2: ......

Page 3: ...regulation of medical devices EU 2017 745 and with the following standards EN 60601 1 2006 A1 2013 AC 2014 Medical electrical equipment Part 1 General Requirements for Basic Safety and Essential Perfo...

Page 4: ...220mm Lifting range of bed surface 450 770mm EL08F Premium Chiropractic Table Length 1800 1950mm Width 660mm Lifting range of bed surface 600 800mm Included angle between head plate and horizontal pl...

Page 5: ...level to reduce the risk of injury caused by the patient falling off the table when unattended Figure 4 Lifting the table Adjusting height of head plate Pull the control lever in the direction indicat...

Page 6: ...ess down on the bed section to achieve the effect of the drop pressure Figure 8 Figure 11 Drop Tension adjustment Use the black knob on the side as indicated below The tension direction is indicated o...

Page 7: ...with adjusting feet for adjusting the height After moving please confirm whether the two adjusting feet are in full contact with the ground otherwise rotate the feet for adjustment Figure 5 Figure 2...

Page 8: ...de the section up down to adjust height and out in to adjust distance up to 18cm or up to 18 degrees Figure 12 Figure 8 Drop Tension adjustment Use the black knob on the side as indicated below Tensio...

Page 9: ...lowest level to reduce the risk of injury caused by the patient falling off the table when unattended Figure 4 Lifting the table Adjusting height of head plate Pull the control lever in the direction...

Page 10: ...Adjustment of bed middle section angle Lift up the pull rod to release the angle adjustment Figure 12 Figure 8 Drop tension adjustment Use the black knob on the side as indicated below Tension directi...

Page 11: ...n a stable status The column at the front side of the base frame is equipped with adjusting feet for adjusting the height After moving please confirm whether the two adjusting feet are in full contact...

Page 12: ...release the angle adjustment Figure 10 Figure 7 Adjustment of bed tail section angle Lift up the pull rod to release the angle adjustment Adjust the black knob indicated by the arrow and the tail sect...

Page 13: ...t Check the wheel immobilization system RECYCLING If you need to dispose of the table or any of its parts or accessories consult and respect the laws and regulations applicable to waste management and...

Page 14: ...e gas SHUTDOWN PROCEDURE Adjust the bed to a suitable position to ensure that the patient is safely left then turn off the power Contraindication Please note that our beds are not sterilized Please do...