8.
Set up/installation
ATTENTION!
The relevant standards must be observed.
For use below the backwash level:
/
Guide the discharge line with a loop above the backwash level.
/
If the base of the discharge line loop is more than 5 m above the lifting unit, an additional
checkvalve must be installed.
/
Provide shut off valves.
/
Every drain must be fitted with an odour trap.
Also see installation dimensions (chapter 18, page 46 - 47, figure 14).
8.1
For ground set up
ATTENTION!
/
The set up must be made frost-free and on level ground.
Connection of discharge pipe
/
Use a PVC discharge pipe with an outside diameter of 25 or 32 mm.
/
Push the pipe to about 16 mm into the rubber sleeve (use a lubricant if necessary) and secure it on
the outside with the existing hose clamp.
Figure 1
Fitting of non-return valve
A
= Flow must follow direction of arrow.
C
= Flap must hinge from the top with arrow
pointing down.
Figure 2
1
2
3 4
A
C
Pos
Description
1
Non-return valve
2
Discharge line (right)
3
Discharge line (left)
4
Cap for unused end of
discharge line
1
2
3 4
A
C
37
Summary of Contents for FLOW CUT BOX
Page 25: ...20 Ersatzteile Abbildung 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 25...
Page 49: ...20 Spare parts Figure 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 49...
Page 73: ...20 Pi ces de rechange Illustration 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 73...
Page 97: ...20 Reservedeler Figur 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 97...
Page 121: ...20 N hradn d ly Obr zek 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 121...
Page 145: ...20 P talkatr szek 16 bra 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 145...
Page 169: ...20 Piezas de repuesto Figura 16 1 2 3 10 4 5 14 15 6 11 16 17 12 13 8 9 8 7 169...
Page 171: ...171...