ROUTER DESCRIPTION
9
•
for every cables we recommend to bind the bunch according to the following picture,
we recommend for this use:
length of the bunch (combination of power supply and data cables) can
be maximum 1,5 m, if the length of data cables exceeds 1,5 m
or in the event of, the cable leads towards the switch - board, we
recommend installing over - voltage protectors (surge suppressors),
with data cables they mustn't carry cables with reticular tension
~ 230 V/50 Hz,
all signals to sensors must be twisted pairs
Fig. 12: Cable routing
Fig. 13: Cable routing for SL version
•
sufficient space must be left before individual connectors for handling of cables
Fig. 14: Space in front connectors
Fig. 15: Space in front connectors SL version
•
for correct function of the router we recommend to use in the switch-board earth-
bonding distribution frame for grounding of power supply of router, data cables and
antenna,