background image

 
  

ROUTER DESCRIPTION 

18 

5.7.9. 

I/O port 

Panel socket 3pin. 

Pin 

no. 

Signal 

mark 

Description 

Data flow 

direction 

BIN0 

Binary input 

Input 

GND 

Signal ground 

 

OUT0 

Binary output  

Output 

Table 11: Connection of I/O port 

 

Fig. 32: I/O connector 

The user interface I/O is for processing of binary input signal and to control (settings) 

of binary output signal. Binary output is not switched to ground, by default configuration. 

Maximum load binary output is 30V / 100mA. The constant current supplied by the 

binary input is 3 mA. 

Connector I/O cable connect into the I/O connector on the router head and tighten 

locking screws. (See bellow picture) 

 

Fig. 33: Connection I/O cable

 

Circuit example of a binary input or output equipment with router: 

 

Fig. 34: Connection input and output of router

 

  

5.7.10. 

Summary of Contents for ER75i v2 SL

Page 1: ...EDGE router ER75i v2 and ER75i v2 SL USER S GUIDE ...

Page 2: ...ve an influence on the user s safety or the function of the device Attention notice on possible problems which can arise in specific cases Information notice information which contains useful advice or special interest GPL license Source codes under GPL license are available free of charge by sending an email to info conel cz Declared quality system ISO 9001 ...

Page 3: ...tor PWR 12 5 7 3 Antenna connector ANT 13 5 7 4 SIM card reader 14 5 7 5 Ethernet port 14 5 7 6 PORT1 16 5 7 7 PORT2 16 5 7 8 USB port 17 5 7 9 I O port 18 5 7 10 Reset 19 6 First use 20 6 1 Connecting the router before first use 20 6 2 Start router 21 6 3 Router configuration 21 6 3 1 Configuration over web browser 21 6 3 2 Configuration over Telnet 21 7 Technical parameters 22 7 1 Technical para...

Page 4: ...SL version 9 Fig 16 Front panel ER75i v2F 10 Fig 17 Front panel ER75i v2F SL 10 Fig 18 Power connector 12 Fig 19 Connection of power supply connector 12 Fig 20 Connection of power supply 12 Fig 21 External antenna 13 Fig 22 Connecting the antenna 13 Fig 23 Ejected the SIM card 14 Fig 24 Ethernet connector 14 Fig 25 Connection Ethernet cable 15 Fig 26 Example of router connection 15 Fig 27 Connecti...

Page 5: ...iption 10 Table 7 Router status indication 11 Table 8 Connection of power connector 12 Table 9 Connection of Ethernet connector 14 Table 10 Connection of USB connector 17 Table 11 Connection of I O port 18 Table 12 Description of reset and restart router 19 Table 13 Technical parameters of router 22 Table 14 Technical parameters of module 22 Table 15 Technical parameters of processor 23 Table 16 T...

Page 6: ... to extreme ambient conditions Protect the router against dust moisture and high temperature The router should not be used at petrol stations We remind the users of the duty to observe the restrictions concerning the utilization of radio devices at petrol stations in chemical plants or in the course of blasting works in which explosives are used Switch off the router when travelling by plane Utili...

Page 7: ...trical electronic products are recycled using the best available recovery techniques to minimize the impact on the environment This product contains high quality materials and components which can be recycled At the end of it s life this product MUST NOT be mixed with other commercial waste for disposal Check the terms and conditions of your supplier for disposal information ...

Page 8: ...ts of the customer Configuration is done via web interface protected by password The GPRS EDGE router supports creation of VPN tunnels using technologies IPsec OpenVPN and L2TP to ensure safe communication Web interface provides detail statistics about the wireless router activities signal strength detailed log etc Router supports functions DHCP NAT NAT T DynDNS NTP VRRP control by SMS and many ot...

Page 9: ...ents of package The router box and DIN mount are supplied in a metal case in the SL version of the router In addition to the basics it is possible to deliver one or two expansion ports RS232 RS485 RS422 ETHERNET M BUS or CNT Separation columns for mounting expansion boards are included Module can be connected only as follows PORT1 RS232 RS485 422 ETHERNET M BUS CNT PORT2 RS232 RS485 422 M BUS Tabl...

Page 10: ...panel ER75i v2B Fig 3 Front panel ER75i v2B SL Fig 4 Front panel ER75i v2F SL Fig 5 Front panel ER75i v2F SL 5 2 Delivery identification Trade name Type name Other ER75i v2B ER 75i v2 Basic version ER75i v2B SL ER 75i v2 Basic version in the metal box ER75i v2F ER 75i v2 Full version ER75i v2F SL ER 75i v2 Full version in the metal box Table 3 Delivery identification Fig 6 Label ER75i v2B Fig 7 La...

Page 11: ...ossible participation Ordering code Version without optional port ER75i v2F set Version with optional Ethernet port PORT1 ER75i v2F ETH set Version with optional RS232 port PORT1 a PORT2 ER75i v2F RS232 set Version with optional RS485 port PORT1 a PORT2 ER75i v2F RS458 set Version with optional MBUS port PORT1 a PORT2 ER75i v2F MBUS set Version with optional CNT port PORT1 ER75i v2F CNT set Table ...

Page 12: ...ROUTER DESCRIPTION 7 5 4 Basic dimensions plastic box Fig 8 Basic dimensions plastic box 5 5 Basic dimensions aluminum box Fig 9 Basic dimensions metal box ...

Page 13: ...ount router to a switch board the following there is no need to have examination immunity or issues in connection with EMC according to EN 60439 1 ed 2 00 A1 04 For compliance of EN 60439 1 ed 2 00 A1 04 specification it is necessary to observe next assembly of the router to the switch board for whip antennas we recommend to observe a distance of 6 cm from cables and metal surfaces on every side a...

Page 14: ... voltage protectors surge suppressors with data cables they mustn t carry cables with reticular tension 230 V 50 Hz all signals to sensors must be twisted pairs Fig 12 Cable routing Fig 13 Cable routing for SL version sufficient space must be left before individual connectors for handling of cables Fig 14 Space in front connectors Fig 15 Space in front connectors SL version for correct function of...

Page 15: ...or CNT PORT2 RJ45 Connector for connection equipment over RS232 RS485 422 or M BUS only FULL version ANT SMA Connector for connection main antenna USB USB A Host Connector for connection the devices with the router USB supports equipments with PL 2303 and FTDI USB RS232 converter I O 3 pin Connector for connection of the binary input and output SIM1 Holder for first SIM card SIM2 Holder for second...

Page 16: ...cells is exactly 3 dBm Signal strength is from 90 dBm to 113 dBm or difference between neighbours cells is smaller than 3 dBm USR Yellow Function selected by user OUT Green On Binary output active IN Green On Binary input active ETH Green On Off Selected 100 Mbit s Selected 10 Mbit s ETH Yellow On Blinking Off The network cable is connected Data transmission The network cable is not connected PORT...

Page 17: ...reversed polarity without signaling is built into the router The power consumption during receiving is 1W The peak power consumption during data sending is 5 5W For correct operation it is necessary that the power source is able to supply a peak current of 600mA Connector on the power cable connects into the power connector on the router head and tightens locking screws See bellow picture Fig 19 C...

Page 18: ...r on the front panel The router can not operate without the antenna connected labeled as ANT Example of antenna Fig 21 External antenna The antenna with the SMA connector The antenna is connected to screw the antenna connector SMA to SMA connector on the router head See figure below Fig 22 Connecting the antenna ...

Page 19: ...w button to eject the reader holder Insert the SIM card into the reader holder and slide it in the reader See bellow picture Fig 23 Ejected the SIM card 5 7 5 Ethernet port Panel socket RJ45 Pin number Signal mark Description Data flow direction 1 TXD Transmit Data positive pole Input Output 2 TXD Transmit Data negative pole Input Output 3 RXD Receive Data positive pole Input Output 4 5 6 RXD Rece...

Page 20: ...ROUTER DESCRIPTION 15 Ethernet cable plug into the RJ45 connector labeled as ETH See bellow picture Fig 25 Connection Ethernet cable The ETH router connection Fig 26 Example of router connection ...

Page 21: ...ug into the RJ45 connector labeled as ETH See bellow picture Fig 27 Connection PORT1 cable 5 7 7 PORT2 The PORT2 is equipped with one of the offered options ports For PORT2 are available on the interface PORT2 RS232 RS485 422 M BUS PORT2 is fitted only in the FULL version of the router Description connection and examples of optional connection ports can be found in separate manuals expansion ports...

Page 22: ...ative pole Input Output 3 USB data USB data signal positive pole Input Output 4 GND Negative pole of DC supply voltage Table 10 Connection of USB connector Fig 29 USB connector Example of connecting devices with serial interface to the USB router Fig 30 Connection PLC to the router Example of connecting of USB flash disk to the USB router Fig 31 Connection flash memory to the router ...

Page 23: ...input signal and to control settings of binary output signal Binary output is not switched to ground by default configuration Maximum load binary output is 30V 100mA The constant current supplied by the binary input is 3 mA Connector I O cable connect into the I O connector on the router head and tighten locking screws See bellow picture Fig 33 Connection I O cable Circuit example of a binary inpu...

Page 24: ...he router Press RST button Table 12 Description of reset and restart router After green LED starts to blink it is possible to restore initial settings of the router by pressing button RST on front panel After press button RST it is restoration of factory configuration and reboot green LED will be on For pressing the RST button could be used a narrow screwdriver Fig 35 Router reset We recommend to ...

Page 25: ...ary to connect all components needed for the operation of your applications and the SIM card must be inserted See bellow picture The router can not operate without connected antenna SIM card and power supply In operation the router must be connected to the antenna otherwise damage to the router Fig 36 Router connection ...

Page 26: ...n over web browser Monitoring of the status configuration and administration of the router can be performed by means of the web interface which is available after insertion of IP address of the router into the web browser The default IP address of the router is 192 168 1 1 Configuration may be performed only by the user root with initial password root A detailed description of the router settings ...

Page 27: ...ssion 1 W 5 5 W Dimensions 42x76x113 mm DIN 35mm Weight ER75i v2 150 g ER75i v2 SL 280 g Antenna connector SMA 50 Ohm User interface ETH USB PORT1 PORT2 Ethernet 10 100 Mbit s USB 2 0 type A host Optional RS232 RS485 ETHERNET M BUS or inputs outputs I O Optional RS232 RS485 M BUS Table 13 Technical parameters of router 7 2 Technical parameters of module EDGE module Frequency bands EGSM850 EGSM900 ...

Page 28: ... s USB 2 0 interface Table 15 Technical parameters of processor 7 4 Technical parameters of I O port Port IO Binary input reed contact with trigger level 1 3 up to 1 4 V Input Output Binary output 120 mA max 30 V Table 16 Technical parameters of I O 7 5 Technical parameters of expansion port Technical parameters of the expansion ports are to be found in separate manuals for expansion ports ...

Page 29: ...CNT 7 Conel User s manual Expansion port ETH 8 Conel Application guide Expansion port mounting 9 Conel Application guide Programmer guide 9 Possible problems Some network cards are able to be set in situation when it is not possible to connect the router It is possible to solve this problem in the following steps hand by selection communication rates 10 MB s in property network cards connect route...

Page 30: ... DNS server send off Switch log system on and observe where the error turns up Connection fails on Ethernet or connection isn t establishing On ethernet interface of the router it is possible to switch auto negotiation off and set a rate and duplex by hand DynDNS not function In private APN not functional If the same IP address is recorded in your canonic name as dynamically assign address it mean...

Page 31: ...P or IPSec isn t establishing Verify the reason in the log system I switched the router to offline mode by the SMS messag mode after restart Control SMS message doesn t change the router configuration If the router is switched t up to next restart This behaviour is the same for next all control SMS messages ...

Page 32: ...icity During cleaning of the router do not use aggressive chemicals solvents and abrasive cleaners Conel Company hereby declares that the router narrated in this user s guide fits all basic demands of directive 1999 5 EC R TTE Router fits values of coefficient SAR defined by association ICNIRP and values of About protection of health before non ionized radiation Declaration about consistency was i...

Reviews: