39
6.3
MOUNTING THE DOMESTIC WATER STATION
The built-in rotary flange for the domestic water station is supplied with bayonet drill holes. The necessary
seals and screws for this domestic water station have already been mounted.
Do not unscrew the screws!
/
Insert the four flange screw heads through the bayonet drill holes on the built-in rotary flange (see
/
Turn the domestic water station in a clockwise direction as far as it will go (see fig. 5 II).
/
Tighten the four flange screws.
The pipes must be able to safely support the domestic water station. Otherwise mechanical damage or
fractures/bursts can occur in the pipes. This can result in major water damage.
Persons close to the domestic water station are exposed to a health risk due to the large quantities of wa-
ter released.
Therefore, if necessary, the pipes must be additionally fixed or supported.
For convenient operation and maintenance it is absolutely necessary to ensure the given spacings. A space
of at least 250 mm should be maintained above and below the domestic water station. These distances are
necessary to be able to properly carry out the backwashing.
The chapters 6.4 „BACKWASH WATER DISCHARGE OPTIONS“ and 7.3 „BACKWASHING“ must
always be observed!
Select the torque (approx. 10 Nm) so that the gasket closes and the domestic wa-
ter station is not damaged or strained!
Fig. 5: Installing the domestic water station
The unit may only be installed by skilled personnel. The chapter 4.1 “INTENDED
USE” must always be observed!
I
II