28
Safe-Lec 2 Conductor Bar Manual
SECTION 15 - 100 AMP COLLECTOR MOUNTING DETAILS
P/N XA-SLC2-100S-1M Single Collector
When stationary, single collector is rated for 50 continuous on copper or galvanized steel bars, and 25 continuous amps on aluminum-
stainless steel bar.
P/N XA-SLC2-100T-1M Tandem Collector
When stationary, tandem collector is rated for 100 continuous amps on copper or galvanized steel bars, and 50 continuous amps on
aluminum-stainless steel bar.
Tools Needed
• 16mm socket wrench
• Steel rule or suitable tape measure
• 4mm hex wrench
• Cable stripper
Installation
1. Attach collector mounting bracket to a suitable support at the correct setting height (see Figs. 28-1 and 28-2).
2. Remove the collector clamp and place collector on the mounting bracket.
3. Ensure collectors are directly aligned with the center of the conductor bars. Collector arms should be parallel with the running
surface.
4. Replace collector clamp and tighten Bolt 1 and Bolt 2 to a recommended torque of 24.4-27.1 Nm (18-20 ft-lbs).
5. For customer installed cable on the collectors there must be 18” for 100 amp and 19.5” 200 amp of cable length from the exit of
the cable clamp to the entrance of the collector head. Reference the striped cable sections of Figures 28-1, 28-2, 29-1 & 29-2.
Contact Surface
Working
Range
2.75
(69.9)
1.25
(31.8)
4.0
(102)
2
1
Figure 28-1
XA-SLC2-100S-1M Single Collector
Working Range
2.75
(69.9)
1.25
(31.8)
Contact Surface
4.0
(102.0)
2
1
Figure 28-2
XA-SLC2-100T-1M Tandem Collector
NOTE:
Cable length between the exit of the
cable clamp and the cable entry hole
on the collector head should be 18” for
100 Amp Collectors and 19.5” for 200
Amp Collectors to ensure proper head
movement on the collectors.