26
5.3.2 Mounting the humidifier
Procedure
1. Mark the attachment point “A” on the wall.
2. Drill hole for attachment point “A” (diameter: 8 mm, depth: 40 mm).
3. Insert the supplied plastic plug, and tighten the screw until the distance between the wall and the
screw head is 4 mm.
4. Unlock the two screws fixing the front panel to the unit, then remove the front panel.
5. Hang up the unit onto the screw and adjust it horizontally and vertically using a spirit level. Then,
mark the fixing points “B”.
6. Drill the holes for the fixing points “B” (diameter: 8 mm, depth: 40 mm).
7. Insert the supplied plastic plugs, and tighten the screws until the distance between the wall and
the screw head is 4 mm.
8. Hang the unit up onto the screws. Before tightening the screws, readjust the unit with the spirit
level.
9. Reattach the front panel and secure it with the two screws.
Dimension
Housing size
small
large
a
189 mm
246 mm
b
61 mm
52 mm
c
490 mm
547 mm
d
120 mm
180 mm
e
120 mm
180 mm
d
e
b
c
a
A
B
B