DIAGRAM OF POSSIBLE CONNECTIONS
Attention!
Voltage of heating components 230V
Attention!
In all cases connection the protective conductor must
be connected to the terminal
PE
Recommended type of
connecting wire
1
In the case of a 230 V mains single-phase
connection with a neutral conductor, the
jumpers connect terminals 1 - 2 - 3 and
4 - 5, protective conductor on
1N
H05VV-F3G4
3X 4 mm2
2
In the case of a 230 V mains single-phase
connection with a neutral conductor, the
jumpers connect terminals 1 - 2 - 3 and 4 - 5,
protective conductor on
2N
H05VV-F4G2,5
4X 2,5 mm2
3
In the case of a 400/230 V mains three-phase
connection with a neutral conductor, the
jumpers connect terminals 4 - 5, the phase
conductors connected to 1. 2 and 3, the
neutral conductor to
4 - 5, protective
conductor
3N
H05VV-F5G1,5
5X 1,5 mm2
Shock conductors - L1 = r, L2 = S, L3 = T, neutral conductor, PE - protective conductor
Positioning the cooker
• The kitchen room must be dry and airy, and must have effective ventilation in accordance with the applicable
technical regulations.
• The room should be equipped with a ventilation system to remove fumes generated during burning. This installation
should include a ventilation grille or hood. Hoods must be installed in accordance with the operating instructions
supplied with them. The position of the cooker should guarantee free access to all controls.
• The room should also have a supply of air, which is necessary for proper burning (combustion) of the gas. The air
supply should not be less than 2 m³/h per 1 kW of burner output. Air can be supplied by direct flow from the outside
through a duct with a cross section of min. 100 cm², or directly from adjacent rooms, which are equipped with
ventilation ducts leading outwards.
• The furniture around the cooker must have a lining and an adhesive for gluing it resistant to a temperature of 100
°C. Failure to comply with this condition may cause the surface to deform or the lining to peel off. If we are not sure
about the heat resistance of the furniture, it is necessary to install the cooker with furniture at a distance of about 2
cm. The wall behind the cooker must be adapted to withstand high temperatures. During use of the cooker, its rear
wall may heat up to a temperature about 50 °C higher than the ambient temperature.
1
2
3
5
4
PE
L1
N
1
2
3
5
4
L1
L2
PE
N
1
2
3
5
4
L1
L2
PE
N
L3
Summary of Contents for SVE6550ss
Page 2: ......
Page 7: ...7 SVE6550ss SVE6550wh CZ ...
Page 26: ...26 SVE6550ss SVE6550wh CZ ...
Page 50: ......
Page 73: ...73 LV SVE6550ss SVE6550wh ...
Page 74: ......