19
Parameter settings
MENU ITEM
DELIVERY
SETTING
AVAILABLE SETTINGS
REMARKS
Event Log
-
Read-only.
See Section 7.2 for a list of the major events
Setting Smoke Time
5 seconds
5 to 360 seconds in 1 second
intervals.
See Section 3.1.
Setting Panic Smoke Time
0 seconds
5 to 360 seconds in 1 second
intervals.
See Section 3.1.
Invert Trigger Mode
Set, Alarm &
Hold-off
N/C Mode.
Panic
N/O Mode
N/O Mode
N/C Mode
Trigger inputs can be individually set to:
N/O Mode = unit detects a normally open circuit
going closed to activate.
N/C Mode = unit detects a normally closed circuit
going open to activate.
See Section 5.5.
Enable/Disable Battery
Enable
Disable
Enable
The PCB-mounted battery switch is “Off” on
delivery.
See Section 5.8.
Enable/Disable ESM
Disable
Disable
ESM
Extreme
Energy Saving Mode.
See Section 5.2.
Smoke Delay
0 seconds
0 to 60 seconds in 1 second
intervals.
See Section 3.1.
Re-triggering
Delay
Delay
Instant
Available if Smoke Delay set to > 0 seconds.
Select Delay to apply set Smoke Delay time to
every re-trigger by the Hold-off.
Instant = no delay.
See Section 3.1.
Settle Timer
0 seconds
0 to 60 seconds in 1 second
intervals.
See Section 3.1.
Verify Timer
0 seconds
0 to 3600 seconds in 5
second intervals.
See Section 5.3.
EN Mode
-
Nil.
Manufacturer-only setting.
Live Temperature
-
Read only.
Displays the current heater block temperature.
Manufacturer Setting
-
Nil.
Manufacturer-access only.
Reboot System
No
No
Yes
Available only if “Service Mode” active.
Reboots the Smoke Screen (all settings are
retained).