The VXH264 can be remotely controlled using a Concept Pro VA- keyboard. Up to 254
VXH264s can be controlled using a single VA- PTZ controller.
SYSTEM ID: If more than one VXH264 is connected on the same RS485 bus, each one must
have a unique ID.
PROTOCOL: Must be set to VA-.
BAUD RATE: Must be set to match the baud rate of the VA- PTZ controller.
SYSTEM: CONTROL DEVICE
SYSTEM NAME: A system name of up to 15 characters can be defined. It is used so that
notification emails can be identified.
F/W UPGRADE: Firmware updates may be released periodically to enhance system
performance and add extra features. The operator can upgrade the firmware using a USB
memory stick.
FACTORY DEFAULT: If settings have been changed which causes erratic behaviour, the factory
default settings can be loaded.
SYSTEM DATA: System settings can be saved to a USB memory stick. The settings can be
reloaded in case of accidental factory reset or can be transferred to another VXH264 if multiple
units need to be installed with the same settings. All information is saved including network
settings and system name.
PASSWORD: Selects if a password is required ‘ON / OFF’.
Please note: Password must be selected to ‘ON’ if USER MANGEMENT options are required.