36
COMUNELLO
®Copyright 2019 - All rights reserved
6 MENU DESCRIPTION AND PROGRAMMABLE FUNCTIONS
The control unit has a MAIN MENU and three sub-menus called EXTENDED to personalise programming and the various system functions.
THE “LEV” LED STATUS INDICATES WHICH MENU IS ACTIVE
Pressing the SELECT button several times in succession you can scroll through the menu displayed by the 7 LEDs to choose the desired function
(flashing LED correspondingly flashing) and change its functionality with the SET button (the LED becomes fixed with function enabled or, conversely,
off with function disabled).
The first available menu is the MAIN menu summarized in Tab no. 2:
MAIN MENU
• Press the SELECT button and select the desired function
from the main menu
The LEV function LED stays on FIXED:
LIVEL 0 - MAIN MENU
LED
FUNCTION
DESCRIPTION
LED ON
LED OFF
DEFAULT
L1
STEP BY STEP
Selection of the opening
logic
Open-Stop-Close-Stop (it closes after the pause time in a partial opening
phase)
Automatic (Open-Close)
L2
CODE TX
Storage of remote
controls
TX PP
TX P.PED
TX 2CH AUX.
Empty storage
L3
CONDO
Activate the "Condomi-
nium" function
After the first one, the other inputs are ignored during the opening and the
pause time
Disabled function
L4
MOTOR TIME
Storage of the motor
stroke with slowdowns
Stored stroke
30 seconds, without
slowdown (default)
L5
PAUSE TIME
Automatic closing
setting
Automatic closing period stored
Disabled function
L6
DELAY
Adjustment of the delay
between the 2 leaves
Door delay enabled (Not resettable)
Door delay disabled
L7
AUTO PROGRAM
Self-learning of the stro-
ke with slowdowns
Memorized self-learning of the stroke
Disabled function
Table 2
The second menu is the one defined as
EXTENDED 1
and to access the programmable functions follow the instructions given in
Tab. 3:
EXTENDED
MENU 1
• Press the SELECT button and scroll the LED menu until
you reach the LEV LED;
• Press SET once to access the EXTENDED menu 1.
The LED of the LEV function FLASHES with this frequency
LIVEL 1 - EXTENDED MENU 1
LED
FUNCTION
DESCRIPTION
LED ON
LED OFF
DEFAULT
L1
HOLD-TO-RUN
Hold-to-run input
Enabled function
Disabled function
L2
PEDESTRIAN /SINGLE LEAF
PUSHBUTTON
Configuration of pushbuttons
inputs PP and PPED
Opening and closing with two
different buttons
PP: Open / Close button
PPED: Single leaf
Leaf with partial / pedestrian
opening
PP: Open / Close
PPED: partial opening
Partial opening/pedestrain leaf
PP: Start / Stop
PPED: partial open of MOT1
L3
PEDESTRAIN BUTTON / DS3
Configuration of the PPED
input as partial opening or as
additional photocell input
Configuration of N.O. PPED input as DS3 N.C. photocells
input (inversion in OPEN)
Configuration of the PPED input
as N.O. Pedestrian input
L4
PHOTOTEST
Perform the photocell test
before each movement
Enabled function
Disabled function
L5
DS2 STOP IN CLOSE
Configuration of DS2 photo-
cells input
STOP in CLOSE once the contact is open, then reversal
Reversal in CLOSE
L6
DS1 PARTIAL INVERTION
Configuration of DS1 photo-
cells input
Partial reversal in CLOSE
Complete reversal in CLOSE
L7
BLOCK / 8K2
Configuration of N.C. STOP or
8.2 K Ohm resistive input.
8.2 K Ohm resistive input configuration
N.C. STOP pushbutton
Table 3
The third menu is the one defined as
EXTENDED 2
and to access the programmable functions follow the instructions given in
Tab. 4
: