10
A) SENS. CODE (Wired sensor test)
The control unit can be used to check the operation of the connected sensors, and to make sure the rotation
direction is correct. When installing the device, we recommend the blind/window is placed in an intermediate
position so that you can see all confirmation movements during the test procedures. After checking the sen-
sors are operating correctly, you must remember to disable the Wired sensor test. Anemometer: manually
rotate the Anemometer blades; at the same time, the control unit will cause an upward movement lasting 5
seconds. Sun sensor test: expose the Sun sensor to natural or artificial light; at the same time, the control
unit will cause the SUN LED to light up and there will be a downward movement lasting 5 seconds. Block
the Sun sensor; at the same time, the control unit will cause the SUN LED to switch off and there will be an
upward movement lasting 5 seconds. Rain sensor test: wet the sensitive part of the Rain sensor; at the same
time, the control unit will cause the RAIN LED to light up and there will be an upward movement lasting 5
seconds. When you have completed the test, make sure you have dried the sensitive part of the Rain sensor
before using the control unit in its normal operating mode. Programming: The control unit is supplied by the
manufacturer with the Wired sensor test disabled. If you wish to enable the Wired sensor test, proceed as fol-
lows: check that the extended menu is enabled (SUN and RAIN LEDs flash alternately), use the “SEL” button
to navigate to SENSOR CODE LED when flashing and press the “SET” button: the SENSOR CODE LED lights
up and programming is complete. Repeat the procedure to restore the initial configuration.
B) T. MOT. (Automatic Movement Lock)
The control unit enables the prevention of automatic movements (Up / Down movements on the Sun Sensor
command or Automatic Sensors function), so that if a Stop command is sent during movement, the control
unit momentarily locks the Automatic movements until a new Up or Down command is sent. The control unit
is supplied by the manufacturer with the Automatic Movement Lock disabled; to enable the function proceed
as follows: check that the extended menu is enabled (SUN and RAIN LEDs flash alternately). Using the “SEL”
button, navigate to T.MOT LED when flashing and press the “SET” button: the T.MOT LED lights up and pro-
gramming is complete. Repeat the procedure to restore the previous configuration.
C) WIND SPEED (Safety upward movement)
The control unit is supplied by the manufacturer with the Safety Upward movement function disabled; if you
wish to enable the function, so that after 12 hours of Wind sensor inactivity the control unit automatically
sends a command for Safety upward movement, proceed as follows: check that the extended menu is enabled
(SUN and RAIN LEDs flash alternately), use the “SEL” button to navigate to WIND SPEED LED when flashing
and press the “SET” button: the WIND SPEED LED lights up and programming is complete. Repeat the proce-
dure to restore the previous configuration.
Summary of Contents for MOWIN
Page 14: ......
Page 15: ...MCU ENGLISH...
Page 28: ......
Page 29: ...MCU FRAN AIS...
Page 42: ......
Page 43: ...MCU DEUTSCH...
Page 56: ......
Page 57: ...MCU ESPA OL...
Page 70: ......
Page 71: ...MCU...
Page 73: ...3 3 60335 2 103 A11 H05RN F 0 75 2 1 2...
Page 75: ...5 4 4 1 T1 T2 T3 T4 4 4 2 T1 T2 T1 T2 4 3 T3 T4 T3 T4 5 5 1 T3 T4 GND 5 2...
Page 76: ...6 5 3 v 10 10 5 4 5 5 SW1 SW1 SW1 1 1 2 T1 T2 3 1 2 2 2 2 1 2...
Page 77: ...7 6 SEL 15 SET SEL 1 2 3 2 4 betpa 25 5 6 7 8...
Page 78: ...8 8 1 4 SEL SET SET SET 2 SEL 5 5 25 5 40 25 SEL SET SEL 5 SET 5 25 3 SEL SET...
Page 79: ...9 9 4 ON SEL SET 7 SET 5 30 SEL SET 30 1 2 3 4 5 6 7 8...
Page 80: ...10 10 A 5 5 5 5 SEL SET B SEL SET...
Page 81: ...11 11 C 12 SEL SET D SEL SET E SEL SET SEL SET...
Page 84: ...Notes...
Page 85: ...Notes...