Alwaysmakesurethatthecablesbetweentheswitchesandattacheddevices

(forexample,switch,hub,orworkstation)arelessthan100meters(328

feet).YoushoulduseCategory5cableorhigher.

Connecting the SFP Port

You can connect an SFP transceiver to Port 6. Comtrol recommends using 

Comtrol-approved SFP transceivers. Cross-connect the transmit channel at 

each end to the receive channel at the opposite end as illustrated in the 

figure.
MakesurethatyouuseanSFPfibertransceivercompliantwithUL

certificationandEN60825Class1.

LED INDICATORS

LED 

Status

Description

PWR1/2

Green

The terminal block is receiving power

Off

The terminal block is not receiving power

(table continued on next page)

6

A

B

TX

RX

TX

RX

Summary of Contents for ROCKETLINX ES7206-XT

Page 1: ...QUICK INSTALLATION GUIDE 2000584 Rev E Release Date March 2014 ROCKETLINX ES7206 XT Industrial PoE Plus Switch ...

Page 2: ...rent protection and accepts a positive or negative power source but PWR1 and PWR2 must be applied with power sources of the same polarity The terminal block accepts 12 24AWG wire Use a UL listed power supply with the required output voltage of 12 36VDC to deliver IEEE 802 3at PoE Plus on all PoE ports Ports 1 4 The power supply must be rated as follows 802 3af 96 Watts Minimum 802 3at 168 Watts Mi...

Page 3: ...d voltage The unit can be configured to signal an alarm for loss of power in either PWR1 or PWR2 2 Tighten the wire clamp screws to prevent the wires from being loosened Note When the ES7206 XT is in operation caution must be taken to not touch the hot surface of the product enclosure Electrical Specifications Value Power Input 12 36VDC Power Consumption without PD loading 840mA 12VDC 420mA 24VDC ...

Page 4: ...acts are on the terminal block connector The alarm relay output contacts are normally open The alarm relay output contacts close when the alarm is enabled with the DIP switches and there is a port link failure or PoE failure on a port The relay contact supports up to 0 5A at 24VDC Do not apply voltage and current higher than the specifications The alarm relay output is controlled by the pre define...

Page 5: ...orresponding port OFF Default Disables port failure alarm for corresponding port 7 ON Enables power event alarm OFF Default Disables power event alarm 8 ON Enables SFP port for 100BASE FX OFF Default Supports Gigabit SFP in SFP port Note After connecting the SFP or changing the speed through DIP 8 cycle the power to activate the SFP Grounding the ES7206 XT Wire the earth ground to ensure the syste...

Page 6: ... cable into the Ethernet port of the ES7206 XT and the other end to the attached networking device Ports 1 4 are Gigabit PoE ports that support IEEE 802 3af 802 3at PoE Port 5 is a Gigabit 10 100 1000BASE TX port Port 6 is a Gigabit SFP port which is discussed in the next section The ports support Gigabit half full duplex All RJ45 ports auto detect the signal from connected devices to negotiate th...

Page 7: ...Comtrol recommends using Comtrol approved SFP transceivers Cross connect the transmit channel at each end to the receive channel at the opposite end as illustrated in the figure Make sure that you use an SFP fiber transceiver compliant with UL certification and EN60825 Class 1 LED INDICATORS LED Status Description PWR1 2 Green The terminal block is receiving power Off The terminal block is not rec...

Page 8: ...s There is a valid Ethernet transmit receive activity to from the connected network device Off The port link is not active P6 LNK Green A network device is attached Blinks There is a valid Ethernet transmit receive activity to from the connected network device Off The port link is not active COMTROL CUSTOMER SERVICE You can use one of the following methods to contact Comtrol Contact Method Web Add...

Reviews: