SLM-3650 Satellite Modem
Revision 3
Installation
MN/SLM3650.IOM
2-9
Table 2-4. 25-Pin D Connector Pinouts
25-Pin D Connector
Pin #
EIA-422
EIA-232
V.35
1 SHLD
SHLD
SHLD
2 SD-A
TXD
SD-A
3 RD-A
RXD
RD-A
4 EIA-A
RTS
RTS
5 CS-A
CTS
CTS
6 DM-A
DSR
DSR
7 SIGGND SIGGND
SIGGND
8 RR-A
DCD
RLSD
9 RT-B
SCR-B
10 RR-B
11 TT-B
SCTE-B
12 ST-B
SCT-B
13 CS-B
14 SD-B
SD-B
15 ST-A
ST
SCT-A
16 RD-B
RD-B
17 RT-A
RXC
SCR-A
18 LL
LL
LL
19 EIA-B
20* MC-A
MC
MC-A
21 DF
DF
DF
22 DM-B
23* MC-B
MC-B
24 TT-A
TXC
SCTE-A
25 MF
MF
MF
*Note:
Use the MASTER clock for EXTERNAL clock input. This clock input
should equal the data rate unless the Asymmetrical Loop Timing Option (ASLT)
is available. The ASLT option allows selection of different clock rates that vary
from the digital data rate. Refer to the Utility/Modem Type/Modem Options
menu for the ASLT option information.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com